Extending OS and RS Motor Cables
-L10, -S10 & -P10 motors are shipped with 10 ft (3 m) cables;
-FLY motor is shipped with 1 ft (0.3 m) flying leads.
-NPS motor does not include cable/leads; 10-foot: use 18 AWG (0.75 mm
2
) wire for
current levels below 10 amps and 16 AWG (1.5 mm
2)
for up to 12 amps..
LVD COMPLIANCE: Maximum DC resistance between the ZETA6xxx’s “EARTH”
terminal (“protective conductor terminal”) and motor body must not exceed 0.1
Ω
.
(This criteria must be taken into consideration when sizing cross-section (gage)
for extended cable lengths.) See Appendix C for more LVD information.
NON-LVD: Maximum extended length is 200 ft (61 m), but cables longer than 50
feet (15 m) may degrade performance. See table below for guidelines:
Max. Current
< 100 ft (30 m)
100-200 ft (30-60 m)
Motor Type
(amps)
AWG
mm
2
AWG
mm
2
OS2HB(S)
1.51
22
0.34
20
0.50
OS2HB(P)
3.01
22
0.34
20
0.50
OS21B(S)
1.88
22
0.34
20
0.50
OS21B(P)
3.75
20
0.50
18
0.75
OS22B(S)
2.14
22
0.34
20
0.50
OS22B(P)
4.00
20
0.50
18
0.75
RS31B(S) 2.32 20
0.50 18 0.75
RS31B(P) 4.65 18
0.75 16 1.50
RS32B(S) 3.10 20
0.50 18 0.75
RS32B(P) 5.81 18
0.75 14 2.50
RS33B(S) 3.48 18
0.75 16 1.50
RS33B(P) 6.97 16
1.50 14 2.50
RS42B(S) 6.19 16
1.50 14 2.50
RS42B(P) 12.00 14
2.50 12 4.00
RE42B(S) 3.48 18
0.75 16 1.50
RE42B(P) 7.35 16
1.50 14 2.50
TS31B(S) 3.48
18
0.75
16
1.50
TS31B(P) 6.97
16
1.50
14
2.50
TS32B(S) 3.10
20
0.50
18
0.75
TS32B(P) 6.19
16
1.50
14
2.50
TS33B(S) 5.81
18
0.75
14
2.50
TS33B(P) 12.00
14
2.50
12
4.00
TS41B(S) 6.58
16
1.50
14
2.50
TS41B(P) 12.00
14
2.50
12
4.00
TS42B(S) 6.97
16
1.50
14
2.50
TS42B(P) 12.00
14
2.50
12
4.00
TS43B(S) 6.97
16
1.50
14
2.50
TS43B(P) 12.00
14
2.50
12
4.00
RS31C(S) 2.26
20
0.50
18
0.75
RS31C(P) 4.00
18
0.75
16
1.50
RS32C(S) 2.88
20
0.50
18
0.75
RS32C(P) 4.00
18
0.75
16
1.50
RS33C(S) 3.50
18
0.75
16
1.50
RS33C(P) 4.00
18
0.75
16
1.50
RS42C(S) 3.26
20
0.50
18
0.75
RS42C(P) 4.00
18
0.75
16
1.50
RE42C(S) 3.38
20
0.50
18
0.75
RE42C(P) 4.00
18
0.75
16
1.50
RS43C(S) 4.00
18
0.75
16
1.50
RS43C(P) 4.00
18
0.75
16
1.50
(
S)
= Series Configuration (P) = Parallel Configuration
NOTE
: Rated current in wire sizes shown may result in a maximum temperature rise of 18°F (10°C) above ambient.
CAUTION: Cables longer than 50 feet (15m) may degrade performance.