13
VAC-SIF-05
Training & Maintenance Manual
CVX0260B
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Male (Pins)
3
1.) Drain
2.) V+
3.) V-
4.) CAN-H
5.) CAN-L
4
5
2
1
Female (Sockets)
3
2
1
4
5
Male (Pins)
1.) 24VDC
2.) Not Used
3.) Not Used
4.) Common
3
4
2
1
Female (Sockets)
2
1
3
4
24VDC Power Connections
DeviceNet Connections
DeviceNet™ Bus Connectors
5-Pin Mini-Style
The DeviceNet™ power bus supplies power for the DeviceNet
circuitry and the two sensors. The auxiliary power bus pro-
vides power for the vacuum solenoids and blow-off solenoids.
No external PLC programming is required for Air Economizing
Functions because this function is built into the electrical unit.
The following are power requirements for the DeviceNet cir-
cuitry. Voltage Range: 12.5 to 24VDC; Current 150 mA.
Input Data Table
Bit
0
1
2
3
4
5
6
7
Input Byte 1
CH1
CH2
Not Used
Not Used
Not Used
Not Used
Not Used Not Used
Part Presence Part Presence
I/O Data Tables
Output Data Table
Bit
0
1
2
3
4
5
6
7
Output Byte 1
CH1
CH1
CH2
CH2
Not Used
Not Used
Not Used Not Used
Vacuum
Blow-Off
Vacuum
Blow-Off
DeviceNet™