background image

P

OW E R

  C

O N NE C T I O N S

 

B

E F O RE

  Y

O U

 S

TA RT

 

This document covers the steps necessary 
for a basic start up of the 

DC

590+DRV drive.  

Drive start ups should be performed by 
qualified electrical technicians who are 
familiar with DC drives and their applica-
tions. For detailed safety, installation, ad-
vanced features and applications on the 
590+, refer to the Product Manual. 
Ensure that all local electric codes are met 
while installing the drive. Check that all live 
parts are covered to protect against electric 
shock and that unexpected rotation of the 
motor will not result in bodily harm or injury. 
This document expects that the drive is 
already installed in its intended location and 
that all relevant installation procedures 
have been followed. Please ensure that the 
drive has adequate ventilation so that ambi-
ent temperature does not exceed 45°C 
(112°F) under normal operating conditions. 
To access the bottom layer, slide off the 
bottom terminal cover and unfasten the two 
retaining screws. Hinge the plastic body 
upwards and engage the support bar.

 

• 

3-phase supply to L1, L2, L3 

• 

Motor armature to A+, A- 

• 

Motor fields to F+, F- 

• 

Motor thermistor to Th1, Th2 

• 

Control supply to L, N. Check 
drive nameplate for correct aux 
voltage supply rating 

• 

Blower to BL1, BL2, BL3, if fitted 

thermistor

thermistor

control  power

control  power

field

field

M

M

armature

armature

3 phase power

3 phase power

Frame 2 (165A) 

C

O NF IGU RE

  I / O  

Under MENU LEVEL\SYSTEM\CONFIGURE I/O, you 

may connect and disconnect internal block diagram con-

nections, to use special functions like PID, winder blocks, 

diameter block, etc., and to tag analog and digital I/O to 

selected points inside the drive to suit your application 

needs. 

S

E R I A L

  L

I N KS

 

Under MENU LEVEL\SERIAL LINKS, you may access 

parameters related to Techboxes, the system port (P3), 

and all the PNO configuration parameters. 

S

E T U P

 P

A R A M E T E RS

 

Under MENU LEVEL\SETUP PARAMETERS, there are 

several submenus where you can enter setup parame-

ters. They are: 

Ramps, Auxiliary I/O, Op Station, Jog/Slack, Raise-

Lower, Preset Speeds, Special Blocks, Field Control, 

Current Profile, Inverse Time, Stop Rates, Calibration, 

Inhibit Alarms, Current Loop, Speed Loop, Standstill, 

Setpoint sum 1. 

Under MENU LEVEL\PASSWORD, you may enter a 

password to protect against unauthorized access to the 

drive setup parameters. Refer to the 590+ product manual 

for details. 

A

L A R M S

  &   P

A S SWO RD

 

Under MENU LEVEL\ALARM STATUS, you may view 

the active and last alarm status. 

A

R M AT U R E

  A

UTOTU NE

 

• 

In the configure drive menu, set Autotune to ARM

 

• 

On the keypad, press L/R for LOCAL mode

 

• 

Ensure that the motor shaft is not allowed to rotate

 

• 

Press RUN. Drive will begin autotuning the armature.

 

• 

When the drive stops and no error message is dis-

played on the MMI, 

 

the autotune was successful. 

• 

Go to MENU LEVEL\SAVE PARAMETERS and save 

your settings. 

F

I E L D

 A

U TOTU NE

 

• 

In the configure drive menu, set Autotune to FLD

 

• 

On the keypad, press L/R for LOCAL mode

 

• 

Press RUN. Drive will begin autotuning the field.

 

• 

When the drive stops and no error message is dis-

played on the MMI, 

 

the autotune was successful. 

Parker Hannifin Corporation 

SSD Drives Division 

9225 Forsyth Park Drive 

Charlotte, NC 28273   USA 

www.SSDdrives.com 

Main (704) 588-3246  Support (704) 602-6062 

HA470388U200   Issue 6 

DC590+ DRV 

Series 

Quick Start 

Frame 2 
165 amps 