P
OW E R
C
O N NE C T I O N S
B
E F O RE
Y
O U
S
TA RT
This document covers the steps necessary
for a basic start up of the
DC
590+DRV drive.
Drive start ups should be performed by
qualified electrical technicians who are
familiar with DC drives and their applica-
tions. For detailed safety, installation, ad-
vanced features and applications on the
590+, refer to the Product Manual.
Ensure that all local electric codes are met
while installing the drive. Check that all live
parts are covered to protect against electric
shock and that unexpected rotation of the
motor will not result in bodily harm or injury.
This document expects that the drive is
already installed in its intended location and
that all relevant installation procedures
have been followed. Please ensure that the
drive has adequate ventilation so that ambi-
ent temperature does not exceed 45°C
(112°F) under normal operating conditions.
To access the bottom layer, slide off the
bottom terminal cover and unfasten the two
retaining screws. Hinge the plastic body
upwards and engage the support bar.
•
3-phase supply to L1, L2, L3
•
Motor armature to A+, A-
•
Motor fields to F+, F-
•
Motor thermistor to Th1, Th2
•
Control supply to L, N. Check
drive nameplate for correct aux
voltage supply rating
•
Blower to BL1, BL2, BL3, if fitted
thermistor
thermistor
control power
control power
field
field
M
M
armature
armature
3 phase power
3 phase power
Frame 2 (165A)
C
O NF IGU RE
I / O
Under MENU LEVEL\SYSTEM\CONFIGURE I/O, you
may connect and disconnect internal block diagram con-
nections, to use special functions like PID, winder blocks,
diameter block, etc., and to tag analog and digital I/O to
selected points inside the drive to suit your application
needs.
S
E R I A L
L
I N KS
Under MENU LEVEL\SERIAL LINKS, you may access
parameters related to Techboxes, the system port (P3),
and all the PNO configuration parameters.
S
E T U P
P
A R A M E T E RS
Under MENU LEVEL\SETUP PARAMETERS, there are
several submenus where you can enter setup parame-
ters. They are:
Ramps, Auxiliary I/O, Op Station, Jog/Slack, Raise-
Lower, Preset Speeds, Special Blocks, Field Control,
Current Profile, Inverse Time, Stop Rates, Calibration,
Inhibit Alarms, Current Loop, Speed Loop, Standstill,
Setpoint sum 1.
Under MENU LEVEL\PASSWORD, you may enter a
password to protect against unauthorized access to the
drive setup parameters. Refer to the 590+ product manual
for details.
A
L A R M S
& P
A S SWO RD
Under MENU LEVEL\ALARM STATUS, you may view
the active and last alarm status.
A
R M AT U R E
A
UTOTU NE
•
In the configure drive menu, set Autotune to ARM
•
On the keypad, press L/R for LOCAL mode
•
Ensure that the motor shaft is not allowed to rotate
•
Press RUN. Drive will begin autotuning the armature.
•
When the drive stops and no error message is dis-
played on the MMI,
the autotune was successful.
•
Go to MENU LEVEL\SAVE PARAMETERS and save
your settings.
F
I E L D
A
U TOTU NE
•
In the configure drive menu, set Autotune to FLD
•
On the keypad, press L/R for LOCAL mode
•
Press RUN. Drive will begin autotuning the field.
•
When the drive stops and no error message is dis-
played on the MMI,
the autotune was successful.
Parker Hannifin Corporation
SSD Drives Division
9225 Forsyth Park Drive
Charlotte, NC 28273 USA
www.SSDdrives.com
Main (704) 588-3246 Support (704) 602-6062
HA470388U200 Issue 6
DC590+ DRV
Series
2
Quick Start
Frame 2
165 amps