Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
13
Manual
Through panel mounting details (all frame sizes)
To allow mounting; first disassemble the drive by following instructions 1 to 4 and then instructions 5 to 7 for mounting:
1. Unscrew and remove mounting bracket(s).
2. Remove Control Module Cover.
3. Remove Control Module.
4. Top & Bottom Cover Removal Instructions.
Frame D only
Top Cover:
Squeeze together the bracket under the top
cover and lift off cover.
Bottom Cover:
After inserting a screwdriver into the slot
slightly push to the left to release the catch.
Frames E, F, G, H and J
Top Cover:
To remove insert a screwdriver into the slot and move to
the right to release the catch, and then slide off cover.
Bottom Cover:
To remove bottom cover insert a screwdriver into the slot
and move to the left to release the catch, and then slide
off cover.
5. Fit gasket to the drive so that an air-tight seal will be
made between the drive and the panel.
Through Panel Kits, can be purchased from Parker
using the following part numbers:
Size D – LA502668
Size E – LA502669
Size F – LA502670
Size G – LA502471
Size H – LA502472
Size J – LA502793
Size K – not applicable
6. Tighten all screws in place as shown, according to panel
insert requirements.
7. At this stage you can wire the power cables.