Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
53
Manual
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
Selected
App
1982 Controller yp
Monitor::Application::Controller Status
REAL
0
-100 to 100
%
NEVER p, p/Q, LS
1983 Controller yi
Monitor::Application::Controller Status
REAL
0
-100 to 100
%
NEVER p, p/Q, LS
1984 Controller yd
Monitor::Application::Controller Status
REAL
0
-100 to 100
%
NEVER p, p/Q, LS
1990 Max p pressure Valve
Setup::Application::Pressure Valve
REAL
0
0 - 500
bar
ALWAYS p, p/Q, LS
Setup::Application::Pressure Valve
Setup::Application::Pressure Valve
1991
Feed Forward pressu-
re Valve
Setup::Application::Pressure Valve
REAL
20
0 - 100
%
ALWAYS p. p/Q, LS
Setup::Application::Pressure Valve
Setup::Application::Pressure Valve
1992
Faktor PID pressure
Valve
Monitor::Application::Digital IOs
BOOL
0.2
0 - 1
%
ALWAYS p. p/Q, LS
1995 Hysteris Bypass
Setup::Application::Bypass Valve
REAL
0
0 - 1000
RPM
ALWAYS
ALL
Setup::Application::Bypass Valve
Setup::Application::Bypass Valve
Setup::Application::Bypass Valve
Setup::Application::Bypass Valve
1996 Bypass open
Monitor::Application::Digital IOs
BOOL FALSE
NEVER
ALL
Monitor::Application::Digital IOs
Monitor::Application::Digital IOs
Monitor::Application::Digital IOs
Monitor::Application::Digital IOs
2000 Filter Analog Input01
Setup::Application::Analog Input Q
TIME
0
0 to 60
S
ALWAYS
ALL
Setup::Application::Analog Input p
Setup::Application::Analog Input pQ
Setup::Application::Analog Input LS
Setup::Application::Analog Input Accu
2001 Filter Analog Input02
Setup::Application::Analog Input Q
TIME
0
0 to 60
S
ALWAYS p. p/Q, LS
Setup::Application::Analog Input p
Setup::Application::Analog Input pQ
Setup::Application::Analog Input LS
2002 Filter Analog Input11
Setup::Application::Analog Input pQ
TIME
0
0 to 60
S
ALWAYS
p/Q
2003 Start
Monitor::Application::Digital IOs
BOOL FALSE
NEVER
ALL
2004 No Stop
Monitor::Application::Digital IOs
BOOL FALSE
NEVER
ALL
2005 Reset
Monitor::Application::Digital IOs
BOOL FALSE
NEVER
ALL
2006 Pump 1 or Switch On
Monitor::Application::Digital IOs
BOOL FALSE
NEVER
ALL
2007 Pump 2 or switch Off
Monitor::Application::Digital IOs
BOOL FALSE
NEVER
ALL
2010 Drive Running Relay01 Monitor::Application::Digital IOs
BOOL FALSE
NEVER
ALL
2011 No Drive Error Relay02 Monitor::Application::Digital IOs
BOOL FALSE
NEVER
ALL
2015 Speed loop Pgain
Monitor::Application::Speed Loop Ctrl
REAL
20
0 to 100
%
ALWAYS p. p/Q, LS
2016 Speed loop I time
Monitor::Application::Speed Loop Ctrl
TIME
0.1
0 to 10
S
ALWAYS p. p/Q, LS
2017 I - Defeat
Monitor::Application::Speed Loop Ctrl
BOOL FALSE
ALWAYS p. p/Q, LS
2018 I – Preset
Monitor::Application::Speed Loop Ctrl
REAL
0
0 -100
%
ALWAYS p. p/Q, LS
2019 Dmd Filter TC
Monitor::Application::Speed Loop Ctrl
TIME
0
0 - 10
S
ALWAYS p. p/Q, LS
2020 Fbk Filter TC
Monitor::Application::Speed Loop Ctrl
TIME
0
0 - 10
S
ALWAYS p. p/Q, LS
2021 Control Word
Monitor:Application:Fieldbus
WORD
0
ALWAYS
ALL
2022 Status Word
Monitor:Application:Fieldbus
WORD
0
NEVER
ALL
2030 DIGIN01 Start
Monitor::Application::Testfunction
BOOL FALSE
ALWAYS
ALL
2031 DIGIN02 No Stop
Monitor::Application::Testfunction
BOOL FALSE
ALWAYS
ALL
2032 DIGIN03 Reset
Monitor::Application::Testfunction
BOOL FALSE
ALWAYS
ALL
2033 DIGIN04 Pump 1
Monitor::Application::Testfunction
BOOL FALSE
ALWAYS
ALL
2034 DIGIN05 Pump 2
Monitor::Application::Testfunction
BOOL FALSE
ALWAYS
ALL
2035 DIGIN04 Switch On
Monitor::Application::Testfunction
BOOL FALSE
ALWAYS
ALL
2036 DIGIN05 Switch Off
Monitor::Application::Testfunction
BOOL FALSE
ALWAYS
ALL
2040 Testmovement
Monitor::Application::Testfunction
BOOL FALSE
ALWAYS
ALL
2041 P1 Testmovement
Monitor::Application::Testfunction
REAL
0
0 - 400
BAR
ALWAYS
ALL
2042 P2 Testmovement
Monitor::Application::Testfunction
REAL
0
0 - 400
BAR
ALWAYS
ALL
2043 Q1 Testmovement
Monitor::Application::Testfunction
REAL
0
0 - 1000
LPM
ALWAYS
ALL
2044 Q2 Testmovement
Monitor::Application::Testfunction
REAL
0
0 - 1000
LPM
ALWAYS
ALL