Manual
Frame K internal dynamic brake switch
Product Code
Motor Power
(kW/hp)
Brake Switch
Peak Current (A)
Peak Brake
Dissipation (kW/
PS)
Brake Switch
Continuous Cur-
rent (A)
Continuous Bra-
ke Dissipation
(kW/hp)
Minimum
Brake Resistor
Value Ω
20 s maximum, 30 % duty
400V Build Variant: 380-480V ±10 %, 50/60 Hz +5 % DC link brake voltage: 765 V
DCP3315
160 / 250
173A
132 / 200
173A
132 / 200
4.4
DCP3380
200 / 300
209A
160 / 250
209A
160 / 250
3.6
DCP3440
250 / 350
262A
200 / 300
262A
200 / 300
2.9
Digital inputs/outputs
Inputs
Outputs
Range
AIN1:
AOUT1:
Range selected by parameter 0001 from:
Range selected by parameter 0003 from:
0 to 10 V, -10 V to +10 V, 0 to 20 mA, 4 to 20 mA
0 to 10 V, -10 V to +10 V
AIN2:
AOUT2:
Range selected by parameter 0002 from:
Range selected by parameter 0004 from:
0 to 10 V, -10 V to +10 V
0 to 10V, 0 to 20 mA, 4 to 20 mA
Absolute maximum input current 25 mA in current mode
(AIN1 only)
Maximum rated output current in voltage mode 10
mA, with short circuit protection
Absolute maximum input voltage ±24V dc in voltage mode
Impedance
Input impedance:
Load impedance :
Voltage range = 22kW
Voltage range ≥ 1kΩ
Current range = 120R
Current range ≤ 600Ω
Resolution
12 bits (1 in 4096) over full range
11 bits (1 in 2048)
Accuracy
Better than ±1%
Better than ±1%
Sample / Update
Rate
1 ms
1 ms
Analogue inputs/outputs
AIN1 (X11/01), AIN2 (X11/02), AOUT1 (X11/03), AOUT2 (X11/04)
Conforming to EN61131-2
Output Voltage
+10V and -10V
Accuracy
Better than ±0.5 %
Output Current
<10 mA
Overload / Short Circuit Protection
Indefinite
Digital inputs
DIN1 (X13/02) – DIN3 (X13/04), DIO1 (X12/01) – DIO4 (X12/04)
Conforming to EN61131-2
Reference outputs
+10VREF (X11/05), -10VREF (X11/06)
Nominal Rated Voltage
24 V
Operating Range
DIN1, DIN2, DIN3, DIO1, DIO2, DIO2, DIO4:
24 V
0-5 VDC = OFF, 15-24 VDC = ON
15 V
(absolute maximum input voltage ±30 VDC)
5 V
0 V
Input Threshold
Typically 10 V
Input Impedance
3.3 kW
Input Current
7.3 mA ± 10% @ 24 V
Sample Interval
1 ms
ON
undefined state
OFF