background image

Parker Hannifin ltd
Industrial division
Dukesway, Team Valley Trading Est
Gateshead, Tyne and Wear
England NE11 0PZ
Tel: +44 (0) 191 402 9000
Fax: +44 (0) 191 482 6296
www.domnickhunter.com

A division of Parker Hannifin Corporation

Copyright Parker Hannifin ltd 2010
Publication Reference: 176034100    01/10 Rev.000

AE – UAE,

Dubai

Tel: +971 4 8127100
parker.me@parker.com

AR – Argentina,

Buenos Aires

Tel: +54 3327 44 4129

AT – Austria,

Wiener Neustadt

Tel: +43 (0)2622 23501-0
parker.austria@parker.com

AT – Eastern Europe,

Wiener Neustadt
Tel: +43 (0)2622 23501 900
parker.easteurope@parker.com

AU – Australia,

Castle Hill

Tel: +61 (0)2-9634 7777

AZ – Azerbaijan,

Baku

Tel: +994 50 2233 458
parker.azerbaijan@parker.com

BE/LU – Belgium,

Nivelles

Tel: +32 (0)67 280 900
parker.belgium@parker.com

BR – Brazil,

Cachoeirinha RS

Tel: +55 51 3470 9144

BY – Belarus,

Minsk

Tel: +375 17 209 9399
parker.belarus@parker.com

CA – Canada,

Milton, Ontario

Tel: +1 905 693 3000

CH – Switzerland,

Etoy

Tel: +41 (0) 21 821 02 30
parker.switzerland@parker.com

CL – Chile,

Santiago

Tel: +56 2 623 1216

CN – China,

Shanghai

Tel: +86 21 5031 2525

CZ – Czech Republic,

Klecany

Tel: +420 284 083 111
parker.czechrepublic@parker.com

DE – Germany,

Kaarst

Tel: +49 (0)2131 4016 0
parker.germany@parker.com

DK – Denmark,

Ballerup

Tel: +45 43 56 04 00
parker.denmark@parker.com

ES – Spain,

Madrid

Tel: +34 902 33 00 01
parker.spain@parker.com

FI – Finland,

Vantaa

Tel: +358 (0)20 753 2500
parker.finland@parker.com

FR – France,

Contamine s/Arve

Tel: +33 (0)4 50 25 80 25
parker.france@parker.com

GR – Greece,

Athens

Tel: +30 210 933 6450
parker.greece@parker.com

HK – Hong Kong

Tel: +852 2428 8008

HU – Hungary,

Budapest

Tel: +36 1 220 4155
parker.hungary@parker.com

IE – Ireland,

Dublin

Tel: +353 (0)1 466 6370
parker.ireland@parker.com

IN – India,

Mumbai

Tel: +91 22 6513 7081-85

IT – Italy,

Corsico (MI)

Tel: +39 02 45 19 21
parker.italy@parker.com

JP – Japan,

Tokyo

Tel: +(81) 3 6408 3901

KR – South Korea,

Seoul

Tel: +82 2 559 0400

KZ – Kazakhstan,

Almaty

Tel: +7 7272 505 800
parker.easteurope@parker.com

LV – Latvia,

Riga

Tel: +371 6 745 2601
parker.latvia@parker.com

MX – Mexico,

Apodaca

Tel: +52 81 8156 6000

MY – Malaysia,

Shah Alam

Tel: +60 3 7849 0800

NL – The Netherlands,

Oldenzaal
Tel: +31 (0)541 585 000
parker.nl@parker.com

NO – Norway,

Ski

Tel: +47 64 91 10 00
parker.norway@parker.com

NZ – New Zealand,

Mt Wellington

Tel: +64 9 574 1744

PL – Poland,

Warsaw

Tel: +48 (0)22 573 24 00
parker.poland@parker.com

PT – Portugal,

Leca da Palmeira

Tel: +351 22 999 7360
parker.portugal@parker.com

RO – Romania,

Bucharest

Tel: +40 21 252 1382
parker.romania@parker.com

RU – Russia,

Moscow

Tel: +7 495 645-2156
parker.russia@parker.com

SE – Sweden,

Spånga

Tel: +46 (0)8 59 79 50 00
parker.sweden@parker.com

SG – Singapore

Tel: +65 6887 6300

SK – Slovakia,

Banská Bystrica

Tel: +421 484 162 252
parker.slovakia@parker.com

SL – Slovenia,

Novo Mesto

Tel: +386 7 337 6650
parker.slovenia@parker.com

TH – Thailand,

Bangkok

Tel: +662 717 8140

TR – Turkey,

Istanbul

Tel: +90 216 4997081
parker.turkey@parker.com

TW – Taiwan,

Taipei

Tel: +886 2 2298 8987

UA – Ukraine,

Kiev

Tel +380 44 494 2731
parker.ukraine@parker.com

UK – United Kingdom,

Warwick
Tel: +44 (0)1926 317 878
parker.uk@parker.com

US – USA,

Cleveland

Tel: +1 216 896 3000

VE – Venezuela,

Caracas

Tel: +58 212 238 5422

ZA – South Africa,

Kempton Park
Tel: +27 (0)11 961 0700
parker.southafrica@parker.com

Parker Worldwide

European Product Information Centre

Free phone: 00 800 27 27 5374

(from AT, BE, CH, CZ, DE, DK, ES, FI, FR, IE,

IT, NL, NO, PL, PT, RU, SE, UK, ZA)

Summary of Contents for DME012-RX

Page 1: ...Medical Air Dryer DME012 RX DME080 RX Original Language User Guide aerospace climate control electromechanical filtration fluid gas handling hydraulics pneumatics process control sealing shielding EN...

Page 2: ......

Page 3: ...llation Commissioning 11 3 1 Locating the equipment 11 3 2 Mechanical Installation 12 3 3 Electrical Installation 12 3 3 1 Mains supply 12 3 3 2 Hygrometer relay 13 4 Operating the equipment 14 4 1 Ov...

Page 4: ...e Most accidents that occur during the operation and maintenance of machinery are the result of failure to observe basic safety rules and proce dures Accidents can be avoided by recognising that any m...

Page 5: ...f not performed correctly may lead to damage to this equipment Highlights actions or procedures which if not performed correctly could lead to electric shock Wear ear protection When disposing of old...

Page 6: ...process is known as Pressure Swing Adsorption PSA Pressure Swing Adsorption PSA A small percentage of dried air is taken from the dryer output flow and is used to regenerate the saturated chamber by e...

Page 7: ...psi 0 1MPa below nominal compressor output pressure The purge air flow is factory set for 6 bar g 87 psi g minimum system pressure Should the minimum supply pressure be lower than this figure the purg...

Page 8: ...32 70 DME015 RX 1003 39 5 302 11 9 284 11 2 960 37 8 352 13 86 37 81 DME020 RX 1168 46 0 302 11 9 284 11 2 1125 44 29 352 13 86 42 92 DME025 RX 1333 52 5 302 11 9 284 11 2 1290 50 79 352 13 86 47 103...

Page 9: ...Remove the equipment from its packaging using the illustrations shown below for guidance and check that it has not been damaged in transit Description Qty DME RX Dryer 1 Dryer Test Certificate 1 If a...

Page 10: ...LY HYGROMETER DEWPOINT RELAY 110VAC POWER SUPPLY HYGROMETER DEWPOINT RELAY DME012 RX DME040 RX DME050 RX DME080 RX A A B B ECO ECO A A B B ECO ECO 3 4 3 4 3 6 4 1 2 1 2 5 5 1 Mains Supply Cable 2 Hygr...

Page 11: ...uitable location for the equipment taking into consideration the minimum space requirements for maintenance and lifting equipment as shown in the diagram below When considering the final location of t...

Page 12: ...rated to at least the maximum operating pressure of the equipment It is recommended that the system be protected with suitably rated pressure relief valves A by pass line may be installed into the sy...

Page 13: ...is supplied with a 3 core non detachable hygrometer relay cable as identified below Warning The mains supply cable and hygrometer relay cables are clearly identified at the cable gland Ensure that the...

Page 14: ...tem pressure slowly open the outlet isolation valve If a bypass line has been fitted close the bypass valve 7 Verify that the column pressure gauges are cycling between zero and full system pressure e...

Page 15: ...ended Service Interval Component Operation Daily Weekly 3 Months 6 Months 12 Months 24 Months 30 Months Dryer Check POWER ON indicator is illuminated Dryer Check STATUS FAULT indicators located on the...

Page 16: ...006 1 Kit Valve Overhaul DME050 RX DME080 RX 608330007 1 E Desiccant Service AA 11 2 Litre Bag 608203661 See table below Kit Column Seals DME012 RX DME040 RX 608203733 1 Kit Column Seals DME050 RX DME...

Page 17: ...DME012 RX DME080 RX 5 4 Service Record Date of Commissioning Service Hours Hours Shown Date Serviced By Comments Observations Print Initials 4 000 8 000 16 000 20 000 24 000 28 000 32 000 36 000 40 0...

Page 18: ...system Check against technical specification Check against technical specification Factory set for 6 bar g 87 psig system pressure domnick hunter trained personnel to adjust Change by domnick hunter...

Page 19: ...95 Generally in accordance with ASMEVIII Div 1 2004 PED Assessment Route B D EC Type examination Certificate LDS 9900792 5 Notified body for PED Lloyds Register Verification 71 Fenchurch St London EC3...

Page 20: ......

Page 21: ...ary Budapest Tel 36 1 220 4155 parker hungary parker com IE Ireland Dublin Tel 353 0 1 466 6370 parker ireland parker com IN India Mumbai Tel 91 22 6513 7081 85 IT Italy Corsico MI Tel 39 02 45 19 21...