11
5 Servicing
The recommended service procedures identified below, along with all other repair and calibration work, should be undertaken by a Parker
Hannifin approved engineer.
5.1 Cleaning
Clean the equipment with a damp cloth only and avoid excessive moisture around any electrical sockets. If required you may use a mild
detergent, however do not use abrasives or solvents as they may damage the warning labels on the equipment.
5.1.1 Service Intervals
Key:
Component
Operation
Da
ily
W
eek
ly
12
Mo
nths
(800
0
H
rs
.)
24
Mo
nths
(16
000
Hrs
.)
36
Months
(24
000
Hrs
.)
Generator
Check the controller display is operating
Generator
Check air flow for fan discharge at the rear of
the equipment.
Generator
Open the manual drain valves on the filters to drain the
condensate.
Generator
Check for leaks within the system
Generator
Check the mains supply cable for damage
Generator
Ensure there is ventilation clearance around
generator
Generator
Replace the inlet and outlet filters.
Recommended Service A
Generator
Replace the cooling fan.
Recommended Service B
Generator
Replace the catalyst assembly.
Recommended Service C
Service
12 Mon
th
s
(8000
Hr
s.
)
24 Mon
th
s
(160
00 Hrs
.)
36 Mon
th
s
(240
00 Hrs
.)
48 Mon
th
s
(320
00 Hrs
.)
60 Mon
th
s
(400
00 Hrs
.)
72 Mon
th
s
(480
00 Hrs
.)
84 Mon
th
s
(560
00 Hrs
.)
96 Mon
th
s
(640
00 Hrs
.)
108
Months
(720
00 Hrs
.)
120
Months
(800
00 Hrs
.)
A
B
C
Check
Essential Procedure
servicereminder.com
Servicereminder.com is a web based reminder service developed to track when service work is due to be carried out. This ensures that parts can be ordered in
advance and that the service is carried out at the optimum time in accordance with the manufacturers recommendations. This service is free to use, simply log on
to
www.servicereminder.com
and select New User Registration.