1
2
3
4
COM
Normally open (N.O.)
Normally closed (N.C.)
P1-P2
DPIT1_VS08MDC1
ELECTRICAL DIFFERENTIAL
PRESSURE INDICATOR
The power supply of the sensor must be
provided by a dedicated voltage source
and not by a distributed dc network.
ELECTRICAL SPECIFICATIONS
VOLTAGE
LOAD
14 V dc
5 (4) A
30 V dc
4 (3) A
125 V ac
5 (3) A
250 V ac
3 (2) A
Min load 5V dc
160 mA
TECHNICAL SPECIFICATIONS
Switching contacts
SPDT
Max pressure (P1=P2)
450 bar
Proof pressure
675 bar
Max differ. pressure (P1-P2)
210 bar
Working temperature
-20° to +100°C
Body material
Brass
Max torque
50 Nm
Protection degree
IP65
INDICATOR SELECTION TABLE
DP SETTING
DP CODE
ORDERING CODE
MARKING CODE
1.2 bar (± 0.25)
G
DPIT1GVS08MDC1
T1 1.2 S08
2.5 bar (± 0.35)
K
DPIT1KVS08MDC1
T1 2.5 S08
3.5 bar (± 0.55)
L
DPIT1LVS08MDC1
T1 3.5 S08
5.0 bar (± 0.75)
M
DPIT1MVS08MDC1
T1 5.0 S08
SEAL KIT
SEAL CODES
ORDERING CODE
Fluoroelastomer
V
930000298
Engraving on Hex.
Pressure setting & thread code
P1: High pressure, P2: Low pressure
Parker reserves the right to change or discontinue any model
or specification at any time and without notice.
Parker Hannifin / Hydraulic Filtration EMEA
Orders and inquiries: please contact your local Parker representative.
20348 C