133
– Pvd3665_Gb_Ex_August 2022
4.5. Troubleshooting
Some symptoms and their possible causes are listed below. This list is not comprehensive.
Whenever an operating incident occurs, consult the relevant servo drive installation
instructions (the troubleshooting display indications will help you in your investigation) or
contact us at:
http://www.parker.com/eme/repairservice
You note that the motor
does not turn by hand
when the motor is not
connected to the drive.
•
Check there is no mechanical blockage or if the motor terminals are
not short-circuited.
•
Check the power supply to the brake.
You have difficulty
starting the motor or
making it run
•
Check on the fuses, the voltage at the terminals (there could be an
overload or the bearings could be jammed), also checks on the load
current.
•
Check the power supply to the brake (+ 24 V ± 10 %) and its polarity.
•
Check on any thermal protection, its connection and how it is set in
the drive.
•
Check on the servomotor insulation (if in doubt, carry out hot and
cold measurements).
The minimum insulation resistance value measured under a max. 50V
DC is 50 MΩ:
•
Between the phase and the casing
•
Between the thermal protection and the casing
•
Between the brake coil and the casing
•
Between the resolver coils and the casing.
You find that the motor
speed is drifting
•
Reset the offset of the servoamplifier after having given a zero
instruction to the speed setpoint input.
You notice that the
motor is racing
•
Check the speed setpoint of the servo drive.
•
Check you are well and truly in speed regulation (and not in torque
regulation).
•
Check the encoder setting
•
Check on the servomotor phase order: U, V, W
You notice vibrations
•
Check the encoder and tachometer connections, the earth
connections (carefully) and the earthing of the earth wire, the setting
of the servo drive speed loop, tachometer screening and filtering.
•
Check the stability of the secondary voltages.
•
Check the rigidity of the frame and motor support..
You think the motor is
becoming unusually hot
•
It may be overloaded or the rotation speed is too low : check the
current and the operating cycle of the motor.
•
Check if the mounting surface is enough or if this surface is not a
heat source
– see §3.6 cooling.
•
Friction in the machine may be too high :
- Test the motor current with and without a load.
- Check the motor does not have thermal insulation.
- Check that there is no friction from the brake when the brake
power is on.
You find that the motor
is too noisy
Several possible explanations :
•
Unsatisfactory mechanical balancing
•
There is friction from the brake: mechanical jamming.
•
Defective coupling
•
Loosening of several pieces
•
Poor adjustment of servo drive or position loop : check rotation in
open loop
Summary of Contents for EX Series
Page 1: ...1 Pvd3665_Gb_Ex_August 2022 Servomotors EX Series Technical Manual PVD 3665 EX...
Page 2: ...2 Pvd3665_Gb_Ex_August 2022...
Page 3: ...3 Pvd3665_Gb_Ex_August 2022...
Page 4: ...4 Pvd3665_Gb_Ex_August 2022...
Page 5: ...5 Pvd3665_Gb_Ex_August 2022...
Page 6: ...6 Pvd3665_Gb_Ex_August 2022...
Page 7: ...7 Pvd3665_Gb_Ex_August 2022...
Page 8: ...8 Pvd3665_Gb_Ex_August 2022...
Page 9: ...9 Pvd3665_Gb_Ex_August 2022...
Page 10: ...10 Pvd3665_Gb_Ex_August 2022...
Page 11: ...11 Pvd3665_Gb_Ex_August 2022...
Page 12: ...12 Pvd3665_Gb_Ex_August 2022...
Page 13: ...13 Pvd3665_Gb_Ex_August 2022...
Page 14: ...14 Pvd3665_Gb_Ex_August 2022...
Page 15: ...15 Pvd3665_Gb_Ex_August 2022...
Page 16: ...16 Pvd3665_Gb_Ex_August 2022...
Page 17: ...17 Pvd3665_Gb_Ex_August 2022...
Page 18: ...18 Pvd3665_Gb_Ex_August 2022...
Page 19: ...19 Pvd3665_Gb_Ex_August 2022 Compliance with UL standards...
Page 20: ...20 Pvd3665_Gb_Ex_August 2022 Compliance with UL standards...
Page 73: ...73 Pvd3665_Gb_Ex_August 2022 3 3 Dimension drawings 3 3 1 EX310E...
Page 74: ...74 Pvd3665_Gb_Ex_August 2022 3 3 2 EX420E EX430E...
Page 75: ...75 Pvd3665_Gb_Ex_August 2022 3 3 3 EX620E EX630E...
Page 76: ...76 Pvd3665_Gb_Ex_August 2022 3 3 4 EX820E EX840E EX860E...
Page 77: ...77 Pvd3665_Gb_Ex_August 2022 3 3 5 EX310 C CCC...
Page 78: ...78 Pvd3665_Gb_Ex_August 2022 3 3 6 EX420 C EX430 C CCC...
Page 79: ...79 Pvd3665_Gb_Ex_August 2022 3 3 7 EX620 C EX630 C CCC...
Page 80: ...80 Pvd3665_Gb_Ex_August 2022 3 3 8 EX820 C EX820 C EX820 C CCC...
Page 81: ...81 Pvd3665_Gb_Ex_August 2022 3 3 9 EX310U...
Page 82: ...82 Pvd3665_Gb_Ex_August 2022 3 3 10 EX420U EX430U...
Page 83: ...83 Pvd3665_Gb_Ex_August 2022 3 3 11 EX620U EX630U...
Page 84: ...84 Pvd3665_Gb_Ex_August 2022 3 3 12 EX820U EX840U EX860U...
Page 93: ...93 Pvd3665_Gb_Ex_August 2022 3 8 5 Mains supply connection diagrams 3 8 5 1 EX310E...
Page 94: ...94 Pvd3665_Gb_Ex_August 2022 3 8 5 2 EX420E EX430E...
Page 95: ...95 Pvd3665_Gb_Ex_August 2022 3 8 5 3 EX620E EX630E...
Page 96: ...96 Pvd3665_Gb_Ex_August 2022 3 8 5 4 EX820E EX840E EX860E...
Page 97: ...97 Pvd3665_Gb_Ex_August 2022 3 8 5 5 EX310 C CCC...
Page 98: ...98 Pvd3665_Gb_Ex_August 2022 3 8 5 6 EX420 C EX430 C CCC...
Page 99: ...99 Pvd3665_Gb_Ex_August 2022 3 8 5 7 EX620 C EX630 C CCC...
Page 100: ...100 Pvd3665_Gb_Ex_August 2022 3 8 5 8 EX820 C EX840 C EX860 C CCC...
Page 101: ...101 Pvd3665_Gb_Ex_August 2022 3 8 5 9 EX310U...
Page 102: ...102 Pvd3665_Gb_Ex_August 2022 3 8 5 10 EX420U EX430U...
Page 103: ...103 Pvd3665_Gb_Ex_August 2022 3 8 5 11 EX620U EX630U...
Page 104: ...104 Pvd3665_Gb_Ex_August 2022 3 8 5 12 EX820U EX840U EX860U...