4.3.1. Cable connection
Please read
§3.8 "Electrical connection"
and
§3.3 “outline drawings”
to get
information about cables connection.
Many useful informations are already available in the drive documentations.
4.3.2. Cable handling
Danger: It is forbidden to disconnect any cable under voltage (high risk
of explosion, damage and sensor destruction).
Warning: Do not touch contacts (risk of damage due to electrostatic
discharges ESD
4.3.3. Use of two grounding devices with EY servomotors
EY servomotors have two equipotential connections for grounding :
•
the first one is connected to the ground pin #2 of power connector,
•
the other one is connected to the external motor housing
(see below).
The connecting of these two grounding devices is mandatory in order
to comply with standard IEC/EN 60079-0.
Danger: before any intervention the drive must be stopped in
accordance with the procedure.