Introduction
Follow these instructions when installing, operating, or servicing
the product.
Application Limits
These products are intended for use in general purpose
compressed air systems only.
With Polyurethane Bowl
kPa PSIG
bar
Operating Pressure Maximum
1034
150
10
Operating Temperature Range
4°C to 49°C
(40°F to 120°F)
With Zinc Bowl
kPa PSIG
bar
Operating Pressure Maximum
2068
300
21
Operating Temperature Range
4°C to 82°C
(40°F to 180°F)
With Zinc Bowl & Wrap Around Sight Gauge
kPa PSIG
bar
Operating Pressure Maximum
1723
250
17.0
Operating Temperature Range
4°C to 66°C
(40°F to 150°F)
ANSI Symbols
Pneumatic Division
Richland, Michigan 49083
269-629-5000
Installation & Service Instructions
IS-L105
L105 Lubricator
ISSUED: September, 2013
Supercedes: July, 2005
Doc. #ISL105, EN #130649, Rev. 2
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to this
product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered by
paint, etc. If masking is not possible, contact your local representative
for replacement labels.
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from The Company, its subsidiaries
and authorized distributors provide product and/or system options for
further investigation by users having technical expertise. It is important
that you analyze all aspects of your application, including consequences
of any failure and review the information concerning the product or
systems in the current product catalog. Due to the variety of operating
conditions and applications for these products or systems, the user,
through its own analysis and testing, is solely responsible for making
the final selection of the products and systems and assuring that all
performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject to
change by The Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.
!
CAUTION
Polyurethane bowls, sight glass and sight domes on
these units may be attacked by certain chemicals. Never
use solvents like carbon tetrachloride, trichlorethylene,
acetone, or paint thinner to clean any parts. These
elements can cause crazing or failure of the plastic parts.
The polyurethane resin parts are compatible with most
hydrocarbon based synthetic lubricants but, before using,
check with the manufacturer of the lubricant or oil for
compatibility with polyurethane resin.
TO CLEAN POLYURETHANE BOWLS USE MILD SOAP
AND WATER ONLY!
!