FL20 Series
106
Note:
11 represents twisted-pair wires.
2 Servodrive has internal 24 VDC power supply. But external 12~24VDC power supply is recommended.
3 DI1~DI8 are programmable input terminals, and DO1~DO4 are programmable output terminals. Users can
redefine these terminals by parameter.
Zero drift: when analog input voltage is 0, zero drift is relative value between servo drive sampling voltage
and reference terminal.
Command source is acquired from servo drive terminal.
Automatic zero set: servo drive can compensate zero drift according to sample value.
Take AI1 as example, following instruction is step to set analog voltage speed.
Start
Set Po001
Po428=0
Over
Set control mode
Set analog speed source
Zero drift
correction
Set Po402 manually or set
zero automatically by
analog channel(Po406)
Set speed
command
corresponding
to ±10V
Set speed(Po400)
corresponding to ±
10V or set Po430-Po433
according to request
b)Related parameter
Parameter
Remarks
Po001
d □ 3
Control mode seletion: analog speed mode
(
1
)
Analog speed mode setting
Po428
Analog speed mode setting
Speed Torque
Setting range
Setting unit
Mfr’s value
When enabled
0~1
N/A
0
Effective Immediate
Setting value
Content
Summary of Contents for FL20-S Series
Page 1: ......
Page 33: ...FL20 S Series 33 M3 structure Fig 3 1 5 Servo drive structure 3 ...
Page 35: ...FL20 S Series 35 M4 structure Approx mass 10 365 kg Fig 3 1 7 Servo drive structure 5 ...
Page 36: ...FL20 S Series 36 M5 structure Approx msaa 11 1Kg Fig 3 1 8 Servo drive structure 6 ...
Page 37: ...FL20 S Series 37 M6 structure Approx mass 17 4Kg Fig 3 1 9 Servo drive structure 7 ...
Page 169: ...FL20 S Series 169 Fig 6 4 44FL20E Cam internal frameworkdiagram ...
Page 347: ...FL20 S Series 347 ...