Note:
1 represents twisted-pair wires.
2 Servodrive has internal 24 VDC power supply. But external 12~24VDC power supply is recommended.
3 DI1~DI8 are programmable input terminals, and DO1~DO4 are programmable output terminals. Users can
redefine these terminals by parameter.
b)
Related parameters
Parameter
Remarks
Po001
d □ 2
Control mode selection: internal register torque mode
Po204
Internal given torque
Internal register torque
Setting range
Setting unit
Mfr’s value
When enabled
-800~800
1% of rated torque
10
Effective Immediate
Note: once internal register torque mode is enabled, servo drive will start running Immediate. Please be
careful!