FL20 Series
145
Rated speed
Target speed
T0
T 0
Po343
Po343
V( r / min)
T(ms)
6.4.5 Position command inhibit function
This function inhibits the servodrive from counting input pulses during position control.
Input position
command
Command pulse
prohibition
ON
ON
OFF
OFF
Actual response
position command
(1) Input signal
Signal name
Code
Default terminal
Remarks
Command
pulse inhibit
INH-P
Must be allocated
Inhibiting the servodrive from counting input pulses,
position pulse command is invalid.
(2) Setting parameters
Parameters
Remarks
Po308
b □□□0
Terminal of inhibiting command pulse is invalid.
b □□□1
Terminal of inhibiting command pulse is valid.
6.4.6 Command pulse clear function
This function clears position deviation register during position control.
(1) Input signal
Signal name
Code Default terminal
Remarks
Pulse clear
CLR
CN3-37 (at the mode of position pulse)
Clearing position deviation register
during position control