FL20 Series
60
+24V
2.2K
330
Ω
PL2
43
15 /PULS
Servo drive
Command controller
Fig 4.3.6 24V open-collector pulse input interface circuit
c)
Wrong example:
Error 1: current-limiting resistor is not connected, which leads to port damaged.
Servo drive
+24 V dc
44
43 PL2
PULS
150R
15 /PULS
12
28 PL1
SIGN
150R
27 /SIGN
External 0 V
Two errors are as below:
1. If 24V internal servo drive is not used, please connect it to external resistor.
2. if 24V internal servo drive is used, please connect to 43/28 pin.
Error 2: When SIGN signal is not connected, direction can not be converted.