WARNINGS FOR INSTALLER AND USER 

 

All  the  operations  indicated  on  these  warnings  must  be  carried  out  by  qualified  staff  according  to  the 
regulations in force. 
This category I 3B/P appliance can only run on 

Butane/Propane

 and does not need any adjustment. 

ATTENTION:

 don’t move the appliance during use or when it is still warm. 

Change deteriorated gas pipes and replace them before expiry date imprinted on 
the pipe.  
Pipes must not be dented in any parts and must be installed in such a way that 
they don’t have to be placed under any strain. 
They must not come into contact with any hot part. 
Nevertheless after connection check that the burner flame is stable and properly 
ventilated. 

Air  regulation  band:

  if  not  already  fitted,  fit  it  as  in  the  photo,  observing  the 

dimension  X=5mm,  which  is  to  be  considered  indicative  and  can  be  modified  in 
relation to the appearance of the flame. 

 

THE GAS BOTTLE SHALL RUN ON A MAXIMUM OF 10 KG. OF BUTANE

 

The label is on the front of the appliance.

 

 

 

WARNINGS FOR INSTALLER

 

 

INSTALLATION OF THE APPLIANCE 

The appliance can be placed on a surface with the following specifications: 
-  the support shall have a temperature resistance of at least 80°C; 
-   ONLY FOR 

OUTDOOR USE 

-  Installation must be carried out following the installation regulations in force 

 

CONNECTION TO GAS SUPPLY 

The appliance operates with butan/propan gas and must be connected using flexible pipes to hose holder. 
The flexible pipe must be in accordance with the particular laws in force. 
The rubber flexible pipe must be in accordance with the standards in force and fixed to hose holder with 
clamp. Pressure regulator of the gas bottle must be in accordance with the regulations in force (

DO NOT 

USE HIGH PRESSURE REGULATORS!

The  installation  of  this  appliance  must  be  carried  out  by  qualified  person  in  accordance  with  the 
requirements  of  the  gas  safety  regulations,  the  local  building  regulations  and  the  by-laws  of  the  local 
undertakings. 
It should also be in accordance with any relevant requirements of the local gas region of LPG supplier, the 
local authority and the relevant recommendations of the standards (latest edition) concerned. 

All  gas  cylinder  connection and  replacement  operations  shall be  performed by  skilled  staff  in  compliance 
with the following observations: 
- Before connecting the cylinder carefully close the burner’s taps and those of the cylinder to be replaced. 
Unscrew the pressure adjuster of the cylinder by unscrewing the nut in clockwise direction. 
- Remove protection hood from the cylinder to be connected and unscrew the closing nut (left threaded). 
The closing tap must not be damaged. 
-  After  checking  if  the  gasket  is  in  place  on  the  cylinder  tap  and  that  no  gasket  is  stuck  to  the  pressure  
adjuster, manually screw the pressure adjuster by turning the nut in anticlockwise direction. 
- Do not turn the adjuster. Make sure that the pipe is not being pulled. 

 