Gemini GV Hardware Installation Guide
Input/Output (I/O) Settings
The I/O settings configure the drive’s three digital inputs, three digital outputs, and
two analog monitors.
Digital Inputs
Command Description
Options:
LH
hard limit disable
hard limits disabled
negative limit only
positive limit only
both hard limits enabled
INLVL
input sense
active high or active low
INDEB
input debounce time
can be set in milliseconds
Digital Outputs
Command Description
Options:
OUTLVL
output sense
active high or active low
Analog Monitors
Command Description
Options:
DMONAV
analog monitor A variable
unused/turn off variable
motor temperature
drive temperature
position error
velocity setpoint
actual velocity
torque/force setpoint
actual (electrical) torque
velocity error
phase A (or U) commanded current
phase A (or U) actual current
phase B (or V) commanded current
phase B (or V) actual current
d-axis commanded current
d-axis actual current
q-axis commanded current
q-axis actual current
DMONAS
analog monitor A scaling
1
you enter a percentage
1
DMONBV
analog monitor B variable
same choices as DMONAV
DMONBS
analog monitor B scaling
1
you enter a percentage
1
1
Monitor output is scalable from -2000% to +2000%, but is limited to
±
10V peak to peak.
Communications Settings
The communication settings configure the drive for RS-232/485 communications.
RS-232/485
Command Description
Options:
ERRLVL
error level
you enter a number
ECHO
echo enable
can be turned on or off
E
listening
can be turned on or off