HY30-8223-INST

7

Parker Hannifin

Pump & Motor Division Europe

Trollhättan, Sweden

Hydraulic Motors

Series V12, V14 and T12

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED 
HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY 
DAMAGE.

This document and other information from Parker-Hannifin Corporation, its subsidiaries and 
authorized distributors provide product or system options for further investigation by users having 
technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection 
of the system and components and assuring that all performance, endurance, maintenance, safety 
and warning requirements of the application are met. The user must analyze all aspects of the 
application, follow applicable industry standards, and follow the information concerning the product 
in the current product catalog and in any other materials provided from Parker or its subsidiaries or 
authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or 
system options based upon data or specifications provided by the user, the user is responsible for 
determining that such data and specifications are suitable and sufficient for all applications and 
reasonably foreseeable uses of the components or systems.

WARNING – USER RESPONSIBILITY

Installation and start-up information

Summary of Contents for GS Global Resources V12 Series

Page 1: ...age for additional support parker com pmde Bulletin HY30 8223 INST EU Installation and start up information Hydraulic Motors SeriesV12 V14 andT12 Effective August 22 2016 Supersedes March 12 2014 V12...

Page 2: ...t positions inter change A to B B to A V14 rotation Refer to the V14 illustration below right valid for all compensators and controls T12 rotation Refer to the V14 illustration below right NOTE Before...

Page 3: ...5 V14 110 max 10 1 6 1 5 5 2 4 5 3 5 V14 160 max 10 1 6 2 5 5 2 5 5 5 Required inlet pressure The motor may operate as a pump under certain conditions When this occurs a minimum pressure must be maint...

Page 4: ...uld always be utilized In order to avoid excessively high case pressure the drain line should be connected di rectly to the reservoir V14 shown V14 shown V14_drain eps Leif A 03 03 11 Fig 1 Fig 2 Fig...

Page 5: ...has reached full operating temperature the motor drain oil viscosity should be above 8 mm2 s cSt At start up the viscosity should not exceed 1500 mm2 s The ideal operating range for the motor is 15 t...

Page 6: ...Parker Motors We suggest the following procedure to run in the V12 V14 T12 motors 1 Start 500 rpm differential pressure 250 bar outlet 10 15 bar 2 Run until the drain temperature has passed its maxim...

Page 7: ...ents and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the application follow applicable industry...

Page 8: ...he proven safety principles according to SS EN ISO13849 2 2008 09 C 2 and C 3 and SS EN 982 A1 2008 so that the machines in which the products are incorporated meet the essential health and safety req...