47
Parker Hannifi n Corporation
Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
Service Manual
HP2 Series Hydrostatic Tandem Pumps
HY13-1521-M1/US
Assembly
Install fi lter
element
Tighten fi lter
element
Install charge
relief ball
35. Lubricate both o-ring seals on fi lter assem-
bly and hand tighten into center block.
36. Tighten fi lter assembly using a 5/8" socket
wrench. Torque fi lter to 12.4–15.8 Nm (110–140
in/lbs).
37. Replace plastic ball (15) in counter bore
charge relief port closest to A and B ports.
46