65
FC05
Capacity of auxiliary
pump 3 unit: mL/r
1
~
260
1
╳
√
√
FC06
Capacity of auxiliary
pump 4 unit: mL/r
1
~
260
1
╳
√
√
FC07
Capacity of auxiliary
pump 5 unit: mL/r
1
~
260
1
╳
√
√
FC08
Capacity of auxiliary
pump 6 unit: mL/r
1
~
260
1
╳
√
√
FC15
Auxiliary pump stop
setting
This is the time in ms
the aux pump will stop
working if there is no
command
from
the
master pump.
15
~
1000
(
unit: ms
)
100
√
√
√
FC16
Max running speed of
sole master pump
0
~
2000(rpm)
Subject
to
model
╳
√
√
FC17
Combined
switching
0
~
2000(rpm)
Subject
to
model
╳
√
√
FC25
Double pump control
0
~
1
0
╳
√
√
FC26
Lower limit of flow of
switching big pump
0.00~1.00
0.08
√
√
√
FC27
Upper limit of flow of
switching big pump
0.00~1.00
0.11
√
√
√
FC30
Delay time of switching
big pump (s)
0.0~999.9
(
S
)
0.2
√
√
√
FC31
Maximum
switching
times in one minute
0~9999
0
√
√
√
FC32
Compulsory unloading
of big pump
0~1
0
√
√
√
FC35
Big
pump
capcacity
ml/r
0.1~260.0
66.0
╳
√
√
FC36
Small pump capcacity
ml/r
0.1~260.0
9.8
╳
√
√
FC37
Internal leakage
compensation
0.000~0.100
0.000
√
√
√
Appendix 2 Expand card
Current signal (0-1A) of moulding machine can be changed into voltage signal (0~10V) by Parker card
Z2A3IQ01, which can be inserted into drive as optional accessory.
Terminal
Name
Function
+15V,-15V,GND
Power source for
Z2A3IQ01
Connect these terminals to control PCB +15V,-15V, GND
terminal as expand card power source. If external power supply
is used, its ground must be connected to GND.