Internal Diagnostics
3 Product description
Instruction book, IQAN- MD3
Internal Diagnostics
The IQAN-MD3 has a diagnostics page. This page can be useful for obtaining
diagnostic information. To view the test page, press the menu and escape buttons
simultaneously and hold during power up. To exit test mode, turn the unit off and
power up normally.
Accessing the diagnostics page.
Safe mode
If necessary, the IQAN-MD3 may be started in safe mode. When started in safe mode,
no application is loaded and nothing is running. The screen shows a default background
and a dialog box notifies the user that the unit is in safe mode. This can be useful for
installing an IQAN-MD3 with an unknown application in memory, when retrofitting of
new hydraulic components has occurred or if a user has somehow changed the
application in an unacceptable way. To start in safe mode, press the escape button and
hold during power up. In safe mode you can then upload a new application to the
IQAN-MD3. To exit safe mode, turn the unit off and power up normally.