20
Voltage inputs
Instruction book, IQAN
Connecting switches to the voltage inputs
It is recommended to connect system vBAT to the input through a switch in
order to reserve 5Vdc VREF for sensors and potentiometers.
EXAMPLE
Connect the positive and negative terminals of the switch to supply or the unit’s
+BAT, and DIN-X, respectively.
Connecting a switch to DIN-X and +BAT.
+BAT
DIN-X
IQAN module
switch