background image

 

For your own safety

 

K-MT1-8_EN_08—2014 

For your own safety 

The dryer has been built in accordance with the state of the art and the 
recognized technical safety regulations. Nevertheless, there is a risk of personal 
injury and damage to property when the dryer is used, if 

 

it is operated by non-qualified personnel,  

 

not used within its intended design specifications, 

 

is repaired or maintained incorrectly. 

 

 

 

 

 

Note: 

For your own safety and to prevent machine damage, please note the 
information and safety notes in these operating instructions when 
working with the dryer.  

 

 

 

 

Signs and hazard areas on the dryer  

Signs and labels 

 

 

Operating data plate 

Type plate of dryer  

 

 

 

 

 

Type plate of upstream filter  

Type plate of downstream filter 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front view 

 

Please note these signs on the dryer. Keep them complete and always legible.  

 

Summary of Contents for K-MT 1-8

Page 1: ...Adsorption dryer ecodry K MT 1 8 Operating instructions Revision 08 2014 EN...

Page 2: ...EC and were subjected to a conformity assessment according to Annex III Module A The assembly consists of pressure appliances according to the classification list attached to the technical documentati...

Page 3: ...ressure equipment 97 23 EC but must not bear the CE mark due to Art 3 Para 3 97 23 EG The quality control system is monitored by Lloyd s Register Quality Assurance GmbH Hamburg code no 0525 The follow...

Page 4: ...ve to keep these appliance data up to date The above stated appliance data provide for a clear identification of the dryer and its components and significantly facilitate any service measures Further...

Page 5: ...on packaging 19 What to do in the case of transport damage occurring 19 Transporting and installing the dryer 20 Storing the dryer 22 Installation 23 Preconditions for installation 23 Connect piping 2...

Page 6: ...nance work to be completed every 12 months 42 Maintenance work to be completed every 24 months 44 Maintenance work to be completed every 48 months 45 Identify and eliminate faults 50 Summary of faults...

Page 7: ...ler Control system Associated documents Operating instructions present Technical documentation see annex Circuit diagrams see separate document Operating manual for installed filters separate document...

Page 8: ...uch damage Danger These danger notes with a grey background warn against personal injury and or danger to life and limb danger notes help you to avoid serious or life threatening situations for yourse...

Page 9: ...personnel not used within its intended design specifications is repaired or maintained incorrectly Note For your own safety and to prevent machine damage please note the information and safety notes...

Page 10: ...carry electrical current These parts may be connected opened and maintained by authorized specialist personnel only Warning against overpressure The entire dryer is under pressure Before commencing an...

Page 11: ...ads They could fracture tear off or become damaged in another way General safety notes For your own safety when carrying out any work on the dryer comply with all applicable national safety regulation...

Page 12: ...en escape of pressure may cause serious injuries Before carrying out any work on the dryer first depressurise the plant Carry out all prescribed tests and checks The factory settings on the control bo...

Page 13: ...supply line and set the ON OFF switch of the dryer to 0 in order to disconnect it from the power supply Afterwards depressurise the dryer see also chapter page 37 The unit may only be restarted after...

Page 14: ...n release of pressure Never remove any parts of the dryer or manipulate the same in any way for as long as the plant is still pressurised A sudden escape of pressure may cause serious injuries Before...

Page 15: ...he dryer dries the compressed air supplied by the compressor and makes it available for industrial use Upstream filters clean the compressed air and remove dust dirt oil and water droplets before the...

Page 16: ...the adsorption At the same time the other chamber is prepared for a renewed take up of humidity This process is called regeneration The regeneration is subdivided into three phases expansion dehumidi...

Page 17: ...the vessels will be effected between the vessels Following switchover the above described process is repeated with the adsorption and regeneration now taking place in the respective different vessel A...

Page 18: ...ain compressed air volume is reached behind the dryer The regeneration process must be continued and ended so that the drying agent does not become unusable prematurely Dewpoint sensing control With a...

Page 19: ...pe of transportation the dryer is delivered in different types of packaging All transportation types the apertures of the dryer are closed off by means of plugs In addition when transportation is effe...

Page 20: ...ation proof It must have the necessary carrying capacity for the weight of the dryer The weight of the dryer is specified in the technical data section of the annex The dryer should be installed with...

Page 21: ...e floor The upright stand profiles of the dryer are provided with pre drilled anchorage bores see figure Use suitable attachment material to anchor the dryer to the floor In the case of vibrating floo...

Page 22: ...nd the installed compressed air outlet valve installed by the owner are both closed and that the dryer is depressurised Disconnect dryer from the compressed air system Disconnect the dryer from the el...

Page 23: ...installed and maintained in a depressurised condition see also the installation example on page 24 All pipes couplings and connections must have the correct diameter and match the operating pressure H...

Page 24: ...ct the dryer to the compressed air system The following figure shows an installation example Compressed air system Item Component 1 Entry humid air 2 Compressed air inlet valve owner end 3 Upstream fi...

Page 25: ...customer Make the electrical supply cable to the dryer voltage free Secure the electrical supply cable to the dryer against switch on Undo bolt 1 on the connector and withdraw connector with seal from...

Page 26: ...inals 1 and 2 on the control board see circuit diagram Hinweis The compressor synchronisation controller is a higher level controller than the pressure dew point controller When both options are in pl...

Page 27: ...ns All shutdown valves of the compressed air inlet and outlet valves installed by the owner in the bypass line if available are closed The dryer is correctly sited and installed Checks before start up...

Page 28: ...55 min maximum Overview of operating and control elements ON OFF switch The ON OFF switch 2 is located to the side of the switchbox and above the mains plug 1 see figure If it is set to 0 the power s...

Page 29: ...the dryer are indicated by means of 4 LEDs Vessel B1 Vessel B2 Regeneration 1 Regeneration 2 Adsorption 1 Adsorption 2 Depending on the operating phase the following LEDs might be on simultaneously Ad...

Page 30: ...t value is flashing With the optional dewpoint sensing control the following error messages might be displayed Display Cause 20 Upper measuring range limit exceeded 999 Dewpoint sensor defective sens...

Page 31: ...l requirements in your country it may be necessary to perform initialisation according to the directive for pressure equipment 97 23 EC Check the dryer regularly for externally visible damage and defe...

Page 32: ...ith our recommendation proceed as follows Ensure that the compressed air outlet valve installed by the owner is closed Keep the compressed air outlet valve closed for the time period recommended above...

Page 33: ...d up phase and prior to switchover during this phase the pressure in both chambers is just below operating pressure so that a fast pressure build up is prevented when the chambers are switched During...

Page 34: ...rol operated in variable cycle mode based on the measured dewpoint of the dried air at the compressed air outlet As soon as a certain dewpoint is reached as the drying agent in the absorbing chamber i...

Page 35: ...x shows the currently measured dewpoint The range of display is 100 C 148 F to 20 C 68 F If the set dewpoint is exceeded the system automatically completes a switchover between the chambers The dewpoi...

Page 36: ...rating chamber is released to ambient pressure If the main valve is opened as the dryer is switched off there is a sudden pressure build up in the chamber This might result in damage to the drying age...

Page 37: ...he dryer by setting the ON OFF switch to position 0 Disconnect dryer from compressed air system Close the compressed air outlet valve installed by the owner If available open bypass line Depressurise...

Page 38: ...it was interrupted Slowly open compressed air outlet valve Avoid a sudden drop in pressure in any circumstance If pressure drops too fast this may cause damage to the dryer Therefore the compressed a...

Page 39: ...ut down and depressurised Bolt connections must be undone with care Note ram pressure values Otherwise emerging media may cause personal injury Do not modify the factory settings of the control system...

Page 40: ...12 months 24 months 48 months see page Complete dryer Carry out visual and function checks 41 Muffler K MT 1 2 Clean muffler replace if necessary 42 K MT 3 8 Mufflers must be replaced annually and af...

Page 41: ...every service kit Each dongle can only be used once Switch off the controller Caution The electric line is still live Do not touch live parts Open the lid to the Multitronic controller The circuit boa...

Page 42: ...ore mufflers must be checked at least once a year and cleaned K MT 1 2 or renewed K MT 3 8 if they are contaminated Warning against sudden air ejection During expansion the pressure is released sudden...

Page 43: ...point measurement it is recommended to replace the dew point sensor every year This period depends however on the actual application and might thus be extended accordingly Dewpoint sensor 1 Warning T...

Page 44: ...lace seal onto sealing face connect adapter 1 and secure it by tightening the screw If no other maintenance work is to be carried out Restart the dryer see page 38 Place the protective caps 4 5 onto t...

Page 45: ...dryer and shut down the unit see page 37 Remove the securing screws at the rear of the check valve plate Insert new balls and new springs and ensure that they are not jammed Replace the seals at the...

Page 46: ...ter stage Solenoid valve For each solenoid valve proceed as follows Remove solenoid valve from the holder 3 Remove the valve together with the solenoid and the diaphragm 4 Insert new diaphragm with gu...

Page 47: ...However in favourable installation conditions the change of drying agent may be carried out at a substantially later date for notes on the installation site see also page 20 The change interval is de...

Page 48: ...e code numbers of the drying agent can be obtained from the manufacturer Dispose of the used drying agent in accordance with all applicable regulations Before filling in new drying agent we recommend...

Page 49: ...achieve an optimum bulk density we recommend using a snowstorm filling pipe available from the manufacturer Subsequently position the perforated plate onto the check valve plate align them properly an...

Page 50: ...d to remedy a fault the owner s specialist personnel or the manufacturer s service engineer Table of possible faults Fault Possible cause Remedy Specialised personnel Service technician No pressure bu...

Page 51: ...ensing control optional Fault code Description of fault Possible cause Remedy Specialised personnel Service technician 20 Upper measuring range limit exceeded Drying capacity exceeded See instructions...

Page 52: ...re 4 Dehumidification explanation 16 Demister maintenance 48 Dewpoint sensing control 18 Differential pressure gauge 15 Digital display explanation 29 Documentation technical 54 Dongle use 41 Dryer ma...

Page 53: ...explanation 17 sudden 31 Pressure Conditions 38 Pressure vessel 39 Programme sequence steps 57 Protection class 55 R Regeneration explanation 16 Regulations for accident prevention 19 20 Replacement...

Page 54: ...2014 Annex with technical documentation This annex comprises the following information and technical documentation Technical data Replacement and wear parts list Logic control diagram Flow diagram Dim...

Page 55: ...lter Downstream filter Nominal Pressure in bare Nominal temperature C K MT 1 8 1 4 GL2XL GL2ZLH 16 50 K MT 2 15 1 4 GL2XL GL2ZLH 16 50 K MT 3 25 1 4 GL2XL GL2ZLH 16 50 K MT 4 35 1 4 GL2XL GL2ZLH 16 50...

Page 56: ...115V SKK1 K4 D2 48 115 K MT 6 to K MT 7 12 and 36 months 115V 230V SKK6 K7 D2 12 Reset module muffler and filter elements K MT 6 to K MT 7 24 months 115V 230V SKK6 K7 D2 24 Reset module valve membran...

Page 57: ...Annex with technical documentation K MT1 8_EN_08 2014 57 Logic control diagram Adsorption in B1 and regeneration in B2...

Page 58: ...Logic control diagram 58 K MT1 8_EN_08 2014 Regeneration in B1 and adsorption in B2...

Page 59: ...Control system 10 102 Perforated plate 80 Upstream filter 10 107 Demister left 90 Downstream filter 10 108 Demister right 100 Muffler 10 109 Left perforated plate Optional devices 10 110 Conical press...

Page 60: ...Dimensional drawing 60 K MT1 8_EN_08 2014 Dimensional drawing Installation on floor...

Page 61: ...101 90 91 11 5 K MT 2 1 4 326 575 540 216 217 551 517 101 101 90 91 15 5 K MT 3 1 4 326 825 790 216 217 801 767 101 101 90 91 20 0 K MT 4 1 4 326 1075 1040 216 217 1051 1017 101 101 90 91 25 0 K MT 6...

Reviews: