4.6 LEDs status
LED
(red)
D1
Error
Status
Off
No error
The EtherCAT communication of the
device is in working condition.
Flickering
Booting error
Booting error was detected. INIT state
reached, but parameter “Change” in
the AL status register is set to 0x01:
change/error.
Blinking
Invalid
configuration
General Configuration Error.
Single Flash Unsolicited
state change
Slave device application has changed
the EtherCAT state autonomously:
parameter “Change” in the AL status
register is set to 0x01: change/error.
Double flash Application
watchdog
timeout
An application watchdog timeout has
occurred.
On
PDI watchdog
timeout
A PDI watchdog timeout has occurred
(green)
D2
Run
Status
Off
Init
The device is in state INIT
Blinking
Pre operational
The device is in state PRE-
OPERATIONAL
Single Flash Safe
operational
The device is in state SAFE-
OPERATIONAL
On
Operational
The device is in state
OPERATIONAL
Flickering
Initialization or
bootstrap
The device is booting and has not yet
entered the INIT state, or the device is
in state BOOTSTRAP. Firmware
download operation in progress
4.7 Address setting
Address setting
Selectors
S1
Address selector “alias”. Digit less significant
S2
Address selector “alias”. Digit more significant
Summary of Contents for MDC Series
Page 1: ...User s manual Rev 0 1 August 2012 MDC MotorNet DC www runcheng net www runcheng net...
Page 13: ...Parker Hannifin Manufacturing Srl user s manual MDC 13 3 3 Motor data...
Page 16: ...Parker Hannifin Manufacturing Srl user s manual MDC 16...
Page 17: ...Parker Hannifin Manufacturing Srl user s manual MDC 17...
Page 18: ...Parker Hannifin Manufacturing Srl user s manual MDC 18...
Page 22: ...Parker Hannifin Manufacturing Srl user s manual MDC 22 4 5 Hybrid cable Connection PSI MDC...