40
BITS 4, 5, 6 AND 8:
These bits are operation mode specific. The description is situated in the chapter of the special
mode. The following table gives an overview:
Bit
Operation mode
Velocity mode
Profile velocity mode
Profile torque mode
4
rfg enable
reserved
reserved
5
rfg unlock
reserved
reserved
6
rfg use ref
reserved
reserved
8
Halt
Halt
Halt
Table 5: Mode specific bits in the
controlword
BITS 9, 10:
These bits are reserved for further use. They are inactive by setting to zero. If they have no
special function, they must be set to zero.
BITS 11, 12, 13, 14 AND 15:
These bits are manufacturer specific.
6.1.2.2
Object 6041
h
: Statusword
The
statusword
indicates the current state of the drive. No bits are latched. The
statusword
consist of bits for:
• the current state of the drive,
• the operating state of the mode and
• manufacturer specific options.
OBJECT DESCRIPTION
INDEX
6041h
Name
Statusword
Object Code VAR
Data Type
UNSIGNED16
Category
Mandatory
ENTRY DESCRIPTION
Access
ro
PDO Mapping Possible
Value Range
UNSIGNED16
Default Value No
Summary of Contents for MDC Series
Page 1: ...User s manual Rev 0 1 August 2012 MDC MotorNet DC www runcheng net www runcheng net...
Page 13: ...Parker Hannifin Manufacturing Srl user s manual MDC 13 3 3 Motor data...
Page 16: ...Parker Hannifin Manufacturing Srl user s manual MDC 16...
Page 17: ...Parker Hannifin Manufacturing Srl user s manual MDC 17...
Page 18: ...Parker Hannifin Manufacturing Srl user s manual MDC 18...
Page 22: ...Parker Hannifin Manufacturing Srl user s manual MDC 22 4 5 Hybrid cable Connection PSI MDC...