Chapter 5 - Connecting to the ViX
The MX80L is designed to be plug and run compatible with the Parker ViX drive. The cables on
the MX80L are labeled to match the labels on the ViX for ease of use and quick installation. When
purchased as part of the part number, the ViX will have the motor parameters already downloaded.
Limits use Inputs
The ViX drive has 5 digital inputs. When using with MX80L, the EOT Limits and Home use 3 of the 5 inputs.
A VM15-PF screw terminal breakout board may be purchased to allow access to the remaining 2 inputs and all
of the outputs.
X2 – FEEDBACK-HALL CONNECTOR
PIN FUNCTION
WIRE
COLOR
1 Encoder
Z+
ORANGE
2 Encoder
Z-
BROWN
3 GND
BLACK
5 +5V
RED
6 Temperature- YELLOW/BLACK
7 Encoder
A+
WHITE
8 Encoder
A-
YELLOW
9 Hall#1 WHITE/BROWN
10 Temp YELLOW/RED
11 Encoder
B-
BLUE
12 Encoder
B+
GREEN
13 Hall#2 WHITE/ORANGE
14 Hall#3 WHITE/VIOLET
X5 – LIMITS CONNECTOR*
PIN FUNCTION WIRE
COLOR
1 GND BLACK
6
+ End of travel
ORANGE
7
- End of travel
BLUE
8 Home GREEN
* For Drive Only versions of the ViX, the limits need to
be connected to the motion controller NOT the drive.
X1 – MOTOR LEADS
WIRE COLOR
DRIVE
RED U
WHITE V
BLACK W
GREEN GND