4
Modular Pneumatic Linear Drives OSP-L
The Type Lable
This plate you can find at OSP-L in the clamping rail of cylinder barrel:
Ø 25-63:
Product monitoring
Our goal is to supply safe, state-of the-art products. Therefore we monitor our products constantly after
delivery. Please inform us immediately of any recurring malfunctions or problems with the OSP-L.
2
Safety
Authorized Use
The operating safety of the OSP-L is only guaranteed if it is used in authorized applications.
Authorized applications of the OSP-L are:
•
To move loads.
•
To exert force.
The OSP-L is driven by compressed air.
The following should also be observed:
•
Conditions laid down in the order confirmation.
•
The Operating Instructions.
•
Cataloque OSP-L.
If the OSP-L is used in any other way, this would constitute an „
Unauthorized Use“.
This could result in property damage or personal injury for which we cannot be held responsible.
The risk is borne by the user alone.
When moving the piston in an unpressurised state, a valve in the middle position can be closed e.g. via an
intake air connection, or a vacuum can occur and pull the inner sealing band into the cylinder barrel via long
supply lines.
This can lead to:
•
excessive leakage
•
non-permitted accelerations (e.g. if fitted in a vertical position).
Caution
When commissioning the cylinder you must ensure that the piston does not come into contact with the com-
pletely vented cylinder barrel! See also chapter 8!
Personnel
The operator of the complete plant must ensure that work on the OSP-L is carried out only by authorized and
qualified personnel. Authorized personnel are trained engineers of the operator, the manufacturer and the
service partner.
Safety-Conscious Working Practices
The contents of these Operating Instructions, particularly the chapter on “Safety Instructions” must be duly
observed under all circumstances.
Before commencing work, all personnel assigned to work with the OSP-L must have read and thoroughly
understood the Operating Instructions - and the chapter on Safety in particular. Doing so while at work is too
late !! This also applies in particular to personnel working occasionally on the OSP-L, e.g., during set-up and
maintenance.
At appropriate intervals, check the safety-awareness of the personnel at work with due observance of the
Operating Instructions.
The followings are not permitted:
•
Unauthorized modifications of the OSP-L.
•
Working methods which impair the safety of the OSP-L.
Observe at the OSP-L :
•
All attached safety instructions.
•
Markings for compressed air connections.
Maintain these instructions in a fully legible condition.
Observe also the manufacturer’s instructions on lubricants, solvents and cleaning agents.
Unit of Measurement [mm]
Country of origin Type
Diameter
Production Order No.
Order No.
Stroke
Variant Code
Customer Order No. Delivery Date
62696281 / GS 45684178-C07 / 29.9.10
DE / OSPL 25 00000 00600 000000000 / 62682099