The insert selected is determined by the type and size of the Phastite
®
connector to be assembled.
1. There are two inserts to select – one for the fixed jaw and one for the
moving jaw (Figure 47). The long insert is installed on the moving jaw
side of the tool. This is the side closest to the 3 yellow cylinders.
Selecting Inserts for the Tri-Tool
®
Installing Inserts on the Tri-Tool
®
1. With the Tri-Tool on a flat and stable work
surface, select the inserts needed (each insert
is colour coded and marked with the size).
Note: the size of the inserts must match the
fittings, tubing, and tubemarker.
2. Identify the 6 cap screws located on the inside
faces of the fixed and moving jaws (3 per jaw)
(Figure 48).
Figure 48
Figure 49
3. Remove the cap screws from each jaw using
a 5mm Allen key. Mount the required insert
into the jaw recess.
4. Ensure correct orientation of the inserts,
where applicable the insert slot should align
with the slot of its corresponding jaw (Figure
49).
5. Replace the cap head screws using the 5mm
Allen key.
Figure 47