Chapter 2: Installing the Monitor
Selecting a Location
PHM/PM User Guide
2-5
Accessing Ports and Other Controls
As shown in Figure 2-1, a +24VDC power input port, touchscreen port,
analog video input port and the on-screen display controls (OSD) are
located on the left side of the unit in all models of the monitor. Be sure to
design your enclosure with these locations in mind.
Figure 2-1: Monitor Ports
Important
To be compliant with CE EMC emission requirements under
EN55011, all video, serial, and parallel port communication
cables must be 100% braided shielded cable.
Radiated Emissions Guidelines
This monitor has been tested to comply with international electromagnetic
and emission standards. To reduce radiated emissions, ensure that there is
a good earth connection to the monitor, you can do this by using the
grounding stud located on the left-side of the chassis. Use the shortest
possible, heavy gage wire or braided cable to make this connection.
Verify low-resistance (<0.5 ohms) continuity with an ohmmeter for proper
grounding. In addition, be sure all communication cables are shielded and
grounded only on one side.
OSD controls
Video
Touchscreen
Power input
Ground stud