background image

isysNet 24 VDC Output Modules, Series A 

E107P

4

Install the Digital Output Module

To Install the Digital Output Module, Proceed as Follows:
  1. Using a bladed screwdriver, rotate the keyswitch on the mounting 

base  clockwise  until  the  number  1  aligns  with  the  notch  in  the 
base.

  2. Position  the  module  vertically  above  the  mounting  base.  The 

module will bridge two bases.

  3. Push the module down until it engages the latching mechanism. You 

will hear a clicking sound when the module is properly engaged.

The locking mechanism will lock the module to the base.

Remove the Digital Output Module From the 
Mounting Base

To Remove the Module from the Mounting Base:
  1. Put a flat blade screwdriver into the slot of the orange latching 

mechanism.

  2. Push the screwdriver toward the I/O module to disengage the 

latch.  The module will lift up off the base.

  3. Pull the module off of the base.

MOD

NET

0

1
2

3

4

5

6

7

PSST8M12A

24V dc     Out

0

1

2

3

4

5

6

7

Module Will Bridge Two Bases

Wire the Output Modules

Following are wiring instructions for the digital output modules.

(view into connector)

Pin 1 - Output 0 

Pin 7 -  Output 6

Pin 2 - Output 1 

Pin 8  -  Output 7

Pin 3 - Output 2 

Pin 9 -  Return (Com)

Pin 4 - Output 3 

Pin 10 - Return (Com)

Pin 5 - Output 4 

Pin 11 - 24VDC

Pin 6 - Output 5 

Pin 12 - Chassis

8

5

4

11

3

2

10

12

6

1

9

7

PSST8M23A

(view into connector)

Pin 1 - 24VDC
Pin 3 - Common
Pin 4 - Output 0 (M8-A) 
 

  Output 1 (M8-B) 

 

  Output 2 (M8-C) 

 

  Output 3 (M8-D) 

 

  Output 4 (M8-E) 

 

  Output 5 (M8-F) 

 

  Output 6 (M8-G) 

 

  Output 7 (M8-H)

PSST8M8A

(view into connector)

Pin 1 - 24VDC
Pin 2 - Output 1 (M12-A) 

Pin 4 - Output 0 (M12-A) 

 

  Output 3 (M12-B) 

 

  Output 2 (M12-B) 

 

  Output 5 (M12-C) 

 

  Output 4 (M12-C) 

 

  Output 7 (M12-D) 

 

  Output 6 (M12-D)

Pin 3 - Common 

Pin 5 - No Connect

PSST8M12A

(view into connector)

Pin 1 - 24VDC
Pin 2 - Input 1 (M12-A) 

Input 9 (M12-E) 

 

  Input 3 (M12-B) 

 Input 11 (M12-F) 

 

  Input 5 (M12-C) 

 Input 13 (M12-G) 

 

  Input 7 (M12-D) 

 Input 15 (M12-H)

Pin 3 - Common
Pin 4 - Input 0 (M12-A) 

Input 8 (M12-E) 

 

  Input 2 (M12-B) 

 Input 10 (M12-F) 

 

  Input 4 (M12-C) 

 Input 12 (M12-G) 

 

  Input 6 (M12-D) 

 Input 14 (M12-H)

Pin 5 - No Connect

PSST16M12A

Summary of Contents for PSST8M23A

Page 1: ...uct or systems in the current product catalog Due to the variety of operating conditions and applications for these products or systems the user through its own analysis and testing is solely responsible for making the final selection of the products and systems and assuring that all performance safety and warning requirements of the application are met The products described herein including with...

Page 2: ...en not in use store the equipment in appropriate static safe packaging ATTENTION Environment and Enclosure This equipment is intended for use in overvoltage Category II applications as defined in IEC publication 60664 1 at altitudes up to 2000 meters without derating This equipment is considered Group 1 Class A industrial equipment according to IEC CISPR Publication 11 Without appropriate precauti...

Page 3: ... 60 7 3 02 76 6 3 13 79 4 5 98 151 9 0 87 22 Drill and Tap for M6 Screw Ground Lug Connection Latching Mechanism Mounting Base Keyswitch Set to position 1 for the PSST8M digital output modules Install the Mounting Base as Follows 1 Lay out the required points as shown above in the drilling dimension drawing 2 Drill the necessary holes for 8 M4 machine or self tapping screws 3 Mount the base using ...

Page 4: ...7 PSST8M12A 24V dc Out 0 1 2 3 4 5 6 7 Module Will Bridge Two Bases Wire the Output Modules Following are wiring instructions for the digital output modules view into connector Pin 1 Output 0 Pin 7 Output 6 Pin 2 Output 1 Pin 8 Output 7 Pin 3 Output 2 Pin 9 Return Com Pin 4 Output 3 Pin 10 Return Com Pin 5 Output 4 Pin 11 24VDC Pin 6 Output 5 Pin 12 Chassis 8 5 4 11 3 2 10 12 6 1 9 7 PSST8M23A vie...

Page 5: ... 2 Output Output 24VDC 500mA 3 Channel 4 Output Output 24VDC 500mA 4 Channel 6 Output Output 24VDC 500mA 5 Channel 8 Output Output 24VDC 500mA 6 Channel 10 Output Output 24VDC 500mA 7 Channel 12 Output Output 24VDC 500mA 8 Channel 14 Output Output 24VDC 500mA 9 24VDC Common Common 24VDC Return 10 24VDC Common Common 24VDC Return 11 24VDC Common Common 24VDC Return 12 24VDC Common Common 24VDC Retu...

Page 6: ...that the PSST8M12A is now under the I O configuration Add 24 VDC Output Modules to RSLogix 5000 I O Configuration To add your output modules to RSLogix 5000 I O configuration follow these steps In RSLogix 5000 For ControlNet highlight the PSSCCNA or 1738 ACNR Shown right click and select New Module For EtherNet IP highlight the PSSCENA or 1738 AENT Shown right click and select New Module ...

Page 7: ... active and under control Flashing Red Open circuit detection No load Off State only Red Short circuit detected On State only Indication Probable Cause Module Status Off No power applied to device Green Device operating normally Flashing Green Device needs commissioning due to missing incomplete or incorrect configuration Flashing Red Recoverable fault Red Unrecoverable fault may require device re...

Page 8: ... IEC 60068 2 2 Test Bb Un packaged Non operating Dry Heat 40 to 85 C 40 to 185 F Relative Humidity IEC 60068 2 30 Test Db Un packaged Non operating Damp Heat 5 to 95 Non condensing Shock IEC60068 2 27 Test Ea Unpackaged Shock Operating 30g Non operating 50g Vibration IEC60068 2 6 Test Fc Operating 5g 10 to 500Hz ESD Immunity IEC 61000 4 2 6kV Contact Discharges 8kV Air Discharges Radiated RF Immun...

Reviews: