background image

RK30880E

Water-In-Fuel (WIF) Detection Kit 

This kit includes new and 
enhanced detection electronics 
built into the probe body and 
works with 12 or 24 volt DC 
systems. 

Once the level of collected 
water rises to make contact 
between the two probe tips, 
a yellow warning light will 
illuminate, indicating time to 
drain water and contaminants 
from the collection bowl. 

Follow draining instructions 
provided with each fuel filter/
water separator to drain the 
collection bowl. After water 
has been drained, the warning 
light will reset and no longer be 
illuminated.

Instruction Part Number 14400 Rev B

Contact Information

Parker Hannifin Corporation

Racor Division

P.O. Box 3208
3400 Finch Road
Modesto, CA 95353

phone  800 344 3286 

209 521 7860

fax 209 529 3278
racor@parker.com

parker.com/racor

Product Features

• Includes a warning light and 

mounting panel

•  WIF housing permanently 

marked for identification

• Built-in detection amplifier
• Circuit board power controller 

(10 volt continuous)

• Reverse polarity protection
• False detection prevention 

(water slosh delay)

• Electromagnetic compatibility 

(EMC)

Summary of Contents for Racor RK30880E

Page 1: ... drain the collection bowl After water has been drained the warning light will reset and no longer be illuminated Instruction Part Number 14400 Rev B Contact Information Parker Hannifin Corporation Racor Division P O Box 3208 3400 Finch Road Modesto CA 95353 phone 800 344 3286 209 521 7860 fax 209 529 3278 racor parker com parker com racor Product Features Includes a warning light and mounting pan...

Page 2: ...y support a 1 amp load so the provided lamp is ideal Should you want this signal to trigger a warning device that draws more than 1 amp use a relay customer supplied to drive the device The yellow wire ground signal should be attached to the coil ground terminal of the relay Once water is detected the ground signal will activate the coil thus closing the power contacts to drive your device horn bu...

Page 3: ...20 UNF threads Probe Assembly Warning Light install in panel 0 50 in 12 7 mm diameter hole Yellow wire to one side of warning light This sends a ground signal Black wire to ground Red wire to 12 24 VDC Connector Assembly Black wire from light kit to 1 amp fuse then to 12 24 vdc Water Probe Port 1 2 20 UNF threads ...

Page 4: ...O PRODUCT OR PART THEREOF THAT IS USED OR BOUGHT FOR USE PRIMARILY FOR PERSONAL FAMILY OR HOUSEHOLD PURPOSES WARRANTIES OF DESCRIPTION WARRANTIES OF MERCHANTABILITY TRADE USAGE OR WARRANTIES OR TRADE USAGE Warning Failure or improper selection or improper use of the products and or systems described herein or related items can cause death personal injury and property damage This document and other...

Reviews: