background image

Battery

+

-

Fuse

12 vdc = 25 amp
24 vdc = 15 amp

Ignition

Switch

Racor

Fuel

Heater

Racor 3-wire Heater

Connection Diagram

Racor ‘3-wire’ fuel heaters have polarity! 

Red wire is for hot (+) 

Black wire is for ground (-) and 

White activates the power relay.

30

86

87

85

black 14

Green 14

red 14

white 18

Optional

Toggle

Switch

Schematic B - For Light Duty Power Relay Kits: RK 11861 and RK 11862

Battery

+

-

Ground

Ignition

Switch

Fuse Box

Rocker

Switch*

Detachable
Connector

Racor 2-wire Heater

Connection Diagram

Schematic C - For Heavy Duty Power Relay Kits: RK 19490-12 and RK 19490-24

Red 18

YLW 18 (2)

Fuse Location
60 amp

Red 10

Black 18

1A Min.

Red 18

Black 14

+
+

+

-

White 18

Fuse Box

1A Min.

Alternator:

Positive (+)
Output Terminal

Racor 

Fuel

Heater

Red 10

Black 10