Shaker Dust Collector
SDC Series
19
6. Troubleshooting
Problem
Possible Cause
Recommended Solutions
Motors for Blower
or Shaker Will Not
Start
Supply Power Not Operational
Check input power to motor circuits for proper
voltage on all legs.
Improper Electrical Wiring
Check and correct internal motor wiring for proper
connections based on the incoming line voltage.
Check control voltage power supply (i.e. fuses,
transformer, overloads etc.).
Dust Emissions
From Clean Air
Discharge
Filter Not Installed Properly
Check to make sure cambars are in the upright and
locked positions. Inspect gasket on underside of
tubesheet for damage.
New Filters are Not Seasoned
Allow filters to seed during normal operation.
Emissions should dissipate after several hours
of dust loading.
Insufficient Airflow
Blower Rotation is Reversed
All blower packages on the SDC should be
rotating clock-wise when looking at the drive
side of the motor.
Leak Downstream of Collection
Hood
Check to make sure the filter access door of the
cabinet is tightly closed. Check the drum connection
and ductwork between the process and collector for
leaking connections.
Filters Plugged
The filters either need to be cleaned or are at the end
of their useful life.
Continual,
Excessive
Pressure Drop
Shaker Cleaning System Not
Functioning Properly
Remove shaker mechanism access panel and
inspect. Make sure all connections are tight and the
drive shaft is securely attached to the shaker fingers.
Dust Storage Drum is Full
Empty drum and clean out hopper.
Filters Plugged
The filters either need to be cleaned or are at the end
of their useful life.
Air Inlet and/or Ducting is
Undersized
Increase air inlet and/or duct size to minimize static
pressure losses. Follow ductwork design methods
as listed in Industrial Ventilation Manual by American
Conference of Governmental Industrial Hygienists.
Summary of Contents for SDC
Page 1: ...Shaker Dust Collector Owner s Manual Model SDC...
Page 6: ...Page intentionally left blank...
Page 8: ...Shaker Dust Collector SDC Series 4 Figure 1 Unit Operation...
Page 10: ...Shaker Dust Collector SDC Series 6 Figure 2 Installation Details 61 10074 1...
Page 14: ...Shaker Dust Collector SDC Series 10 Figure 7 SDC 840 1050 Hopper Assembly 61 10074 14...
Page 25: ...Shaker Dust Collector SDC Series 21 Figure 13 Replacement Parts DWG 61 10074 15...