31
12.0 System Fault Error Messages
The Aquamatic, Aquamatic XL and AquaWhisper DX control system contains fault log message center.
During operation, if a dangerous condition exists, or a critical monitoring component fails which would
result in the control systems inability to accurately detect a dangerous condition. The detected condition
or failure is deemed as a ‘Critical Error’. These types or faults result in a rapid shutdown of the water
maker and all associated equipment. The fault log message center is the information window used by the
operator to examine system faults or failures.
When these operational faults or equipment failure happens, the controller will automatically switch the
display screen to the following information window:
1.
To stop the alarm press, Accept.
System Alarm codes and likely causes
Number Alarm Displayed
Likely Causes
01
Automatic start requested with
system locked in E-Stop. Please
clear E-Stop.
The E-Stop button was pressed in when an automatic
start was requested. Release the E-stop button before
continuing.
02
System emergency stop requested
in automatic mode. All moving
machinery stopped.
The E-Stop button was pressed while the system was
running. Release the E-stop button before attempting
to run the unit again.
03
Automatic start requested with
booster pump running in manual
mode.
The booster pump was running in manually mode, and
the operator requested starting the system in
automatic mode. Stop the booster pump in manual
control screen before re-attempt to start the system in
automatic mode.
Detected system
failure description
Exit message
center by pressing
here
Summary of Contents for Sea Recovery Aquamatic