ENGLISH
4.4.3 CAN Input Module (SCMI-600-02)
The CAN input module (SCMI-600-02) is equipped with two passive
CAN bus connections for external sensors without automatic sensor
detection (external CAN).
INFORMATION
The passive CAN bus connections are galvanically separated from
each other and from the device. Both connections are provided with
connectable terminating resistors.
The passive CAN bus connections are optimally suited to reading
out diesel motor data via the SAE J1939 protocol. Messages from
other CAN protocols can also be read out. In this case, the CAN input
module is passive and cannot be detected by other CAN masters.
The figure indicates the connection ports on the analog input module:
1
2
Fig. 10
CAN input module (SCMI-600-02)
Pos. Designation
Description
1
CAN bus (CAN1xx)
To connect sensors without
automatic sensor detection
2
CAN bus (CAN2xx)
To connect sensors without
automatic sensor detection
168
The Parker Service Master CONNECT V1.0/04/20
Input Modules
Summary of Contents for Service Master CONNECT
Page 1: ...The Parker Service Master CONNECT Bedienungsanleitung Operating Manual ...
Page 107: ...DEUTSCH Abb 55 Gerät Device 107 The Parker Service Master CONNECT V1 0 04 20 Bedienung ...
Page 133: ...DEUTSCH 12 3 Maßzeichnungen 133 The Parker Service Master CONNECT V1 0 04 20 Anhang ...
Page 134: ...DEUTSCH 134 The Parker Service Master CONNECT V1 0 04 20 Anhang ...
Page 135: ...DEUTSCH 135 The Parker Service Master CONNECT V1 0 04 20 Anhang ...
Page 137: ...DEUTSCH 137 The Parker Service Master CONNECT V1 0 04 20 Anhang ...
Page 245: ...ENGLISH Fig 55 Device 245 The Parker Service Master CONNECT V1 0 04 20 Operation ...
Page 271: ...ENGLISH 12 3 Dimensional Drawings 271 The Parker Service Master CONNECT V1 0 04 20 Appendix ...
Page 272: ...ENGLISH 272 The Parker Service Master CONNECT V1 0 04 20 Appendix ...
Page 273: ...ENGLISH 273 The Parker Service Master CONNECT V1 0 04 20 Appendix ...
Page 275: ...ENGLISH 275 The Parker Service Master CONNECT V1 0 04 20 Appendix ...