ENGLISH
6.5.6 Fast Measurement
The
Fast measurement
measuring method (FAST MODE) enables the
recording of measured values from upto four fast channels. In the case
of these fast channels, the measurement is performed at a storage in-
terval of 100 µs.
INFORMATION
The use of the
Fast measurement
measuring method is only pos-
sible with analog external sensors. They must be configured accord-
ingly prior to their use. Refer to Chapter
&
After selecting the fast measurement measuring method, the device
displays a predefined trigger and corresponding parameters to com-
plete the measurement.
1
Tap on the
button.
Ä
The configuration window opens in which to define the param-
eters.
2
Select a trigger and define the parameters trigger according to
your application.
The following settings are available to be defined:
Designation
Description
Storage time
Set the storage time for the measurement.
When the storage time has expired, the mea-
surement stops automatically
Pre-Trigger time
Define the period of time in which the measured
values have already been recorded prior to the
trigger being triggered
Trigger type
Select the trigger type for the measurement
Auto repeat
When the option is activated, the measurement
is started again the next time the trigger is trig-
gered after automatic storage of the previous
measurement
Ring buffer
If this option is activated, the defined memory
area is continuously overwritten by current mea-
sured data
216
The Parker Service Master CONNECT V1.0/04/20
Operation
Summary of Contents for Service Master CONNECT
Page 1: ...The Parker Service Master CONNECT Bedienungsanleitung Operating Manual ...
Page 107: ...DEUTSCH Abb 55 Gerät Device 107 The Parker Service Master CONNECT V1 0 04 20 Bedienung ...
Page 133: ...DEUTSCH 12 3 Maßzeichnungen 133 The Parker Service Master CONNECT V1 0 04 20 Anhang ...
Page 134: ...DEUTSCH 134 The Parker Service Master CONNECT V1 0 04 20 Anhang ...
Page 135: ...DEUTSCH 135 The Parker Service Master CONNECT V1 0 04 20 Anhang ...
Page 137: ...DEUTSCH 137 The Parker Service Master CONNECT V1 0 04 20 Anhang ...
Page 245: ...ENGLISH Fig 55 Device 245 The Parker Service Master CONNECT V1 0 04 20 Operation ...
Page 271: ...ENGLISH 12 3 Dimensional Drawings 271 The Parker Service Master CONNECT V1 0 04 20 Appendix ...
Page 272: ...ENGLISH 272 The Parker Service Master CONNECT V1 0 04 20 Appendix ...
Page 273: ...ENGLISH 273 The Parker Service Master CONNECT V1 0 04 20 Appendix ...
Page 275: ...ENGLISH 275 The Parker Service Master CONNECT V1 0 04 20 Appendix ...