Parker Hannifin S.p.A S.B.C. Division
SLVDN User’s Manual
Page 112 of 181
Par. Description
Field
Def.
b180.10
Electronic CAM2 engaging on master phase 0.
W 0
b180.11
Electronic CAM2 release on master phase 0.
W 0
b180.12
CAM 2 engaging immediately ( Signal lock/Unlock CAM 2).
R 0
b180.13
Electronic CAM2 execution on single shot.
W 0
b180.15
Enable swap table (engage/release linear).
W 0
b181.0
Enabled Tab.0 in the Cam.
=1 TAB0 is enabled.
R 0
b181.1
Enabled Tab.1 in the Cam.
=1 TAB1 is enabled.
R 0
b181.2
Enabled Tab.2 in the Cam.
=1 TAB2 is enabled.
R 0
b181.3
Enabled Tab.3 in the Cam.
=1 TAB3 is enabled.
R 0
b181.4
Command swap of Tab.3 (Tab.3-Tab1-Tab.0).
The switching
between the tables is showed in the picture.
The switching starts from TAB3 to TAB0, clockwise direction.
W 0
b181.5
Command swap of Tab.0 ( Tab.0-Tab2-Tab.3).
The switching
between the tables is showed in the picture.
The switching starts from TAB3 to TAB0, counterclockwise
direction.
W 0
b181.6
Selection Table in the CAM 2.
The state of this bit, together with
bit b181.7, identifies the selected table (see table below*).
W 0
b181.7
Selection Table in the CAM 2.
The state of this bit, together with
bit b181.6, identifies the selected table (see table below*).
* Table selection
b181.6
b181.7
Tab0 1
1
Tab1 1
0
Tab2 0
1
Tab3 0
0
W 0
b181.8
Enable virtual table (Tab.3).
W 0
b181.9
Enable counter position from CAM1 to global counter
(Pr131:130).
This command, b181.9=1, enable the reference of
CAM1. This value is added algebraically to global counter of
reference.
W 0
b181.10
Enable counter position from CAM 2 to global counter (
Pr131:130).
This command, b181.10=1, enable the reference of
positioner. This value is added algebraically to global counter of
reference.
W 0
b181.11
Enable counter position from trapezoidal positioner to global
counter (Pr131:130).
This command, b181.11=1, enable the
reference of CAM2. This value is added algebraically to global
counter of reference.
W 0
b181.13
Enable counter position from CAM 1 to reference position
(Pr60:61).
W 0
b181.14
Enable counter position from CAM 2 to reference position
(Pr60:61).
W 0
b181.15
Enable counter position from trapezoidal positioner to reference
position (Pr60:61).
W 0