Parker Hannifin S.p.A S.B.C. Division
SLVDN User’s Manual
Page 144 of 181
OBJECT DESCRIPTION
INDEX 605Bh
Name
Shutdown option code
Object Code
VAR
Data Type
INTEGER16
Category Optional
ENTRY DESCRIPTION
Access
rw
PDO Mapping No
Value Range INTEGER16
Default Value 0
DATA DESCRIPTION
Value
Description
-32768 ... –1 manufacturer specific
0
Disable drive function
1
Slow down with slow down ramp; disable of the drive
function
2 ... 32767
reserved
13.1.2.4.
Object 605C
h
: Disable operation option code
The parameter
disable operatio
n
option code
determines what action should be taken if there
is a transition OPERATION ENABLE
⇒
SWITCHED ON. OBJECT DESCRIPTION
INDEX
605Ch
Name
Disable operation option code
Object Code VAR
Data Type
INTEGER16
Category
Optional
ENTRY DESCRIPTION
Access
rw
PDO Mapping No
Value Range INTEGER16
Default Value 1
DATA DESCRIPTION
Value
Description
-32768 ... -1 manufacturer specific
0
Disable drive function
1
Slow down with slow down ramp and then disabling of the drive
function
2 ... 32767
reserved