19.Appendix F: Continuous working
In continuous operation, the limit power depends on the voltage of the supply network and of
the model, see the following table. The data are estimated in order to guarantee 20.000 hours
of service average life of the capacitor.
Maximum continuous power without inductance of network:
Supply network
model
1-phase 3-phase
SLVD1N
No derating
No derating
SLVD2N
650W No
derating
SLVD5N
650W 1100W
SLVD7N
650W 1100W
SLVD10N
1850W No
derating
SLVD15N
1850W 4700W
SLVD17N
1850W 4700W
Maximum continuous power with inductance of network:
Supply network
model
1-phase 3-phase
SLVD1N
No derating
No derating
SLVD2N
No derating
No derating
SLVD5N
1000W No
derating
SLVD7N
1000W 1700W
SLVD10N
No derating
No derating
SLVD15N
3000W No
derating
SLVD17N
3000W 4850W
Data of network inductance:
Supply network
model
1-phase 3-phase
SLVD1N
Not necessary
Not necessary
SLVD2N
2,5mH 5Arms 14Ap(sat)
Not necessary
SLVD5N
2,5mH 6,8Arms 17Ap(sat) 1mH 5,5Arms 11Ap(sat)
SLVD7N
2,5mH 6,8Arms 17Ap(sat) 1mH 5,5Arms 11Ap(sat)
SLVD10N
Not necessary
Not necessary
SLVD15N
1,2mH 18Arms 45Ap(sat) 0,5mH 15Arms 30Ap(sat)
SLVD17N
1,2mH 18Arms 45Ap(sat) 0,5mH 15Arms 30Ap(sat)