Parker Hannifin S.p.A S.B.C. Division
SLVDN User’s Manual
Page 73 of 181
Par. Description
Field
Range
Def.
Ris.
Pr19
Peak current.
This is the maximum current that
the converter can supply to the motor. It is
expressed as a percentage of the peak current of
the converter. In general, it should never exceed
three times the rated current of the motor.
R/W
M
0÷100.0
[%Ip]
100.0 0.1%
I
picco
Pr20
DC bus voltage (read-only).
Displays the value
of the voltage present on the DC bus.
R 0÷850
[Volt]
1
Pr21
Torque limiter (read-only).
Can be used by the
operating modes to limit the torque to the motor.
R 0÷100
[%Cn]
1%
Pr22
Auxiliary analogue reference.
The value
displayed will be Pr22=Vin
⋅
100/9.76. The
resolution is of 0.2%.
R ±100
[%]
0.2%
Pr23
Alarm code.
This is the code for the alarm that is
present. Code 0 represents the absence of alarms.
Consult the table of alarm codes for more details.
R 0÷255
Pr24
Latest alarm.
This parameter contains the latest
alarm. Pr24 will be set to 0 during the execution of
the alarm reset command (b99.10).
R
M
0÷255
Pr25
Software version code (read-only).
Indicates the
version of the software that has been installed.
R 0÷255
Pr26
Serial line speed code.
This is the code for
programming the transmission speed. For more
information, consult the section on the serial
interface.
R/W
M
0÷8
5 1
Pr27
Serial line address code.
For more information,
consult the relevant section.
R/W
M
0÷31 0/1
1
Pr28
Motor shaft position (read-only).
Indicates the
absolute position of the resolver.
R 0÷4095
[count]
1
Pr29
Number of motor poles.
R/W
K,M
2÷64
0
1
Pr30
Offset of the resolver position.
Used to correct
electronically the mechanical position of the
resolver.
R/W
M
± 32767
0
1
Pr31
Operating mode.
Used to select the active
operating mode. The value 0 means that no
operating mode has been selected
R/W
M
0÷15
0
1
Pr32
Rated speed.
This is the rated speed of the motor.
The speed that has been set is used to limit the
speed request. Therefore, it should be set to about
10% greater than the maximum operational speed.
R/W
K,M
0÷9000
[rpm]
0
1
Pr33
Rated current of the motor.
. The rated current of
the motor must be set.
R/W
K,M
0.1÷In
[A]
0
0.1
Pr34
Number of poles on the resolver.
R/W
K,M
2÷4÷8
0
1
Pr35
Torque monitor.
Unit = % of the torque at peak
current, resolution 0.1%. Indicates the percentage
of the torque or of the current that the motor is
supplying.
R 0÷100.0
[%]
0.1%