Parker Hannifin S.p.A S.B.C. Division
SLVDN User’s Manual
Page 90 of 181
Par. Description
Field
Range
Def.
Res.
Pr109
Acceleration ramp (positioner)
. This is the
acceleration ramp that will be used during the
positioning profile. If b231.13=0, this parameter
defines the acceleration and deceleration ramps
of the position profile.
R/W 0.002÷
30000
[s/Krpm]
0.5 1
ms
Pr114:115
Actual position (electrical shaft)
. Read-only
parameter. Indicates the actual position with
reference to the electrical shaft.
R [count] 1
Pr116:117
Actual position (positioner)
. Read-only
parameter. Indicates the actual position with
reference to the trapezoidal profile.
R [count] 1
Pr118:119
Final position (positioner)
. Used to set the
final position that is desired for the generator of
the trapezoidal profile, based on 4096 steps per
revolution.
R/W [count] 1
Pr193
Profile selection from Tab.0.
R/W - 0 1
Par. Description
Field
Def.
b150.0
Active positioner.
During the positioning (Pr118:119
≠
Pr116:117) this bit is high.
R/W
M
0
b150.2
Engaged electrical shaft.
During the engaging phase when the
ramp (Pr103) is not 0, this bit indicates the end of the transitory
phase.
R/W
M
0
b150.3
Encoder in selection.
If 0, the encoder input, conditioned by Pr52
and Pr53, is used as the master for the electrical axis function. If
1, it updates directly Pr118:119 to execute the step like function
or pulses train.
R/W
M
0
b150.4
Profile direction.
Read-only flag. Indicates the direction of the
motion of the positioner..
R
M
0
b150.6
Profile feed-forward.
If 1 the profile feed-forward is disabled.
R/W
M
0
b150.8
El. Axis engaging/release.
This bit it used to engage (= 1) and
release (= 0) the axis from the input encoder reference.
R/W
M
0
b150.10
Type 1 reset
. Command to set all the motor position and
reference to 0.
R/W
0
b150.11
Type 2 reset
. Command that sets the position of the motor shaft
(Pr62:63) to the main reference (Pr60:61) and of the positioner
(Pr116:117) by setting that of the electrical shaft to 0.
R/W
0
b150.13
Final position evaluation enable/disable (Pr118:119).
If 0,
eventual modifications to Pr118:119 will not be considered.
R/W
M
1
b231.10
Tab0 enable profile.
R/W 0
b231.13
Enable Pr107.
(1) the parameter Pr107 is enabled as deceleration
ramp, and Pr109 defines only the acceleration ramp of the
position profile.
R/W 0