93 - PVD 3622_GB_TM_January 2014.Docx
3.8. Power Electrical Connections
3.8.1.
Wires sizes
In every country, you must respect all the local electrical installation
regulations and standards.
Not limiting example in France: NFC 15-100 or IEC 60364 as well in Europe.
Cable selection depends on the cable construction, so refer to the
cable technical documentation to choose wire sizes
Some drives have cable limitations or recommendations; please refer
to the drive technical documentation for any further information.
Cable selection
At standstill, the current must be limited at 80% of the low speed
current I
o
and cable has to support peak current for a long period. So, if
the motor works at standstill, the current to select wire size is
2 x 0.8 Io
1,13 x I
o
.
Sizes for H07 RN-F cable, for a 3 cores in a cable tray at 30°C max
Section
I
max
[mm²]
[A
rms
]
1.5
17
2.5
23
4
31
6
42
10
55
16
74
25
97
35
120
50
146
70
185
95
224
120
260
150
299
185
341
240
401
300
461
Summary of Contents for TM Series
Page 1: ...1 PVD 3622_GB_TM_January 2014 Docx Torque Motors TM Series Technical Manual PVD 3622...
Page 57: ...57 PVD 3622_GB_TM_January 2014 Docx 3 3 1 2 Shaft Height 200 mm Thrust bearing 29424...
Page 61: ...61 PVD 3622_GB_TM_January 2014 Docx 3 3 2 2 Shaft Height 315 mm Thrust Bearing 29426...
Page 62: ...62 PVD 3622_GB_TM_January 2014 Docx 3 3 2 3 Shaft Height 315 mm Thrust Bearing 29430...
Page 66: ...66 PVD 3622_GB_TM_January 2014 Docx 3 3 3 2 Shaft Height 400 mm Thrust Bearing 29434...
Page 67: ...67 PVD 3622_GB_TM_January 2014 Docx 3 3 3 3 Shaft Height 400 mm Thrust Bearing 29440...