98 - PVD 3622_GB_TM_January 2014.Docx
3.9. Feedback system
3.9.1.
Resolver
Parker part number
220005P1001
Electrical specification
Values @ 8 kHz
Mounting
Remote system with belt and pulley
Ordering designation
A
Reduction ratio
6 (TM_200)
9 (TM_300)
6 (TM_400)
Polarity
2 poles
Input voltage
7 Vrms
Input current
86mA maximum
Zero voltage
20mV maximum
Encoder accuracy (without belt & pulley)
± 10’ maxi
Ratio
0,5 ± 5 %
Input impedance
Mini 48 + 66j Ω
Typical 56 + 80j Ω
Output impedance (primary in short circuit
whatever the position of the rotor)
Typical 120 + 200j Ω
Dielectric rigidity (50
– 60 Hz)
500 V
– 1 min
Insulation resistance
≥ 100MΩ
Rotor inertia
~30 g.cm²
Operating temperature range
-55
– +155 °C
Resolver connection
PIN
Signal
1
Output voltage S3 (cos-)
2
Output voltage S1 (cos+)
3
4
5
6
7
Output voltage S2 (sin+)
8
Output voltage S4 (sin-)
9
10
Input voltage R1
11
12
Input voltage R2
We do not recommend resolver for TM series due to the low accurate
speed control
Summary of Contents for TM Series
Page 1: ...1 PVD 3622_GB_TM_January 2014 Docx Torque Motors TM Series Technical Manual PVD 3622...
Page 57: ...57 PVD 3622_GB_TM_January 2014 Docx 3 3 1 2 Shaft Height 200 mm Thrust bearing 29424...
Page 61: ...61 PVD 3622_GB_TM_January 2014 Docx 3 3 2 2 Shaft Height 315 mm Thrust Bearing 29426...
Page 62: ...62 PVD 3622_GB_TM_January 2014 Docx 3 3 2 3 Shaft Height 315 mm Thrust Bearing 29430...
Page 66: ...66 PVD 3622_GB_TM_January 2014 Docx 3 3 3 2 Shaft Height 400 mm Thrust Bearing 29434...
Page 67: ...67 PVD 3622_GB_TM_January 2014 Docx 3 3 3 3 Shaft Height 400 mm Thrust Bearing 29440...