Remove &
inspect
commutator
8. Remove commutator (5) and seal ring (4)
Remove seal ring from commutator, using
an air hose to blow air into ring groove until
seal ring is lifted out and discard seal ring.
Inspect commutator for cracks or burrs,
wear, scoring, spalling or brinelling. If any of
these conditions exist, replace commutator
and commutator ring as a matched set.
SEE FIGURE 14 & 15.
Remove
manifold
9. Remove manifold seal ring (3) and discard.
SEE FIGURE 16. Remove the manifold (6)
and inspect for cracks surface scoring, bri-
nelling or spalling. Replace manifold if any
of these conditions exist. SEE FIGURE 17. A
polished pattern on the ground surface from
commutator or rotor rotation is normal.
NOTE
NOTE: The manifold is constructed of
plates bonded together to form an inte-
gral component not subject to further
disassembly for service. Compare con-
figuration of both sides of the manifold to
ensure that same surface is reassembled
against the rotor set.