HY13-1526-001-M1/US
Torqmotor™ Service Procedure
TC, TS, TB, TE and TJ Series
Parker Hannifin Corporation
Hydraulic Pump/Motor Division
Greeneville, TN 37745 US
32
Check coupling
shaft for rust
or corrosion
15. Check exposed portion of coupling shaft
(10) to be sure you have removed all signs
of rust and corrosion which might prevent
its withdrawal through the seal and bearing.
Crocus cloth or fine emery paper may be
used. SEE FIGURE 25. Remove any key (26)
or nut (27a,27b).
Remove seal
ring from
housing
14. Remove and discard seal ring (3) from
housing (17). SEE FIGURE 24.
Figure 25
Figure 24
Figure 23
Figure 22
Disassembly and Inspection
Remove &
inspect
drive link
13. Remove drive link (9) from coupling shaft
(10) if it was not removed with rotor set and
wear plate. Inspect drive link for cracks and
worn or damaged splines. No perceptible
lash (play) should be noted between mating
spline parts. SEE FIGURE 23.
12. If wear plate is still in place then remove the
wear plate seal ring (3) and discard.