Test procedure
Use a test stand that supplies a flow of about 30 l/min.
and pressures of up to 300 bar.
A secondary flow of 3 – 5 l/min. at a pressure of 25 bar
is required to supply low pressure for externally sup-
plied controls.
EP control requires an amplifier supplying correct cur-
rent according to specification.
Test
1. Fill housing with hydraulicfluid and start the pump in
thetest stand.
2. Increase the pressurewith the restrictor valve onthe
return line. Max allowedpressure is 150 bar/2150 psi.
3. Check the drain flow andcompare with the table.
Test procedure
M
Pump
Q ~30 lpm
V16-220/270
max drain flow
6 lpm
Max 220 bar /
3100 psi
V16
Max 150 bar /
2150 psi