100 VIX AE SERVO DRIVE USER GUIDE
SV
Save configuration
Syntax
Units
Range of ‘n’
Default
See also
aSV
-
-
-
Z
Description
When the SV command is issued, the current drive system variables and
configuration are stored in non volatile memory. Following a reset or power-
cycle the settings held in the non-volatile memory will be restored into the
drive.
Wait 1-2 seconds before sending any other command following an SV.
Properties
Immediate
Example
1RFS
;return drive to factory settings
1MP
;set drive to position mode (step/direction control)
1SV
;save current settings
1Z
;reset drive
1M
;report current drive mode
*MP
Note
This command will not operate whilst the motor is being commanded to
move.
Summary of Contents for ViX250AE
Page 2: ......
Page 57: ...50 VIX AE SERVO DRIVE USER GUIDE...
Page 123: ...116 VIX AE SERVO DRIVE USER GUIDE...
Page 135: ......