Digital Power Amplifier
Series VRD350 and VRD355
Installation Manual
5
IA VRD UK.INDD RH 02.06
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
General
Design
Europe format
Electrical
Supply voltage
[V] 18...30, ripple < 5%
Current consumption
[A] 3
Power consumption (24V)
[VA] 50
Pre-fuse
[A] 3.15 quick acting
Inputs
Analogue Feedback value
[V] 6 ±2, 600kOhm
Feedback value
[V] 7.5 ±2, 600kOhm
Feedback value
[V] 0...10, > 10MOhm
Feedback value
[V] 0...±10, > 10MOhm
Feedback value
[mA] 0...20, 100kOhm
Feedback value
[mA] 4...20, 100kOhm
Command value 5/6
[V] 0...±10, > 150kOhm
Digital 0
[V] 0...1
1
[V] 3...30
Outputs
Ext. supply voltage
[V] 24 ±10%, ripple <5%
Reference
[V] +10, -10, 10mA
Analogue
[V] 0...10, 5mA
Digital
[mA] 50
Solenoids
[A] 0.8 / 2.7 / 3.5
Interfaces
Serial
RS 232C
Adjustment range
Min
[%] 0...100
Max
[%] 0...100
Ramp time
[s] 0...39.5
Dither Amplitude
[%] 0...30
Frequency
[Hz] 0...647, in steps
Zero point
[%] -30...+30
Protection class
Industrial protection class
IP00
Environment conditions
Temperature
[°C] 0...50
Connection
Plug connector
DIN 41612, 48pin design type F
Cable dimensions
AWG 15 (power solenoid); 20 (all others)
Cable length
[m] max 50
Dimensions
Front panel
[mm] 50.5 x 128.4, 10TE/3HE
Printed circuit board
[mm] 100 x 160
1.1. Technical Data
EN 50081-2
EN 50011
EN 50082-2
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EMC