6
IA VRD UK.INDD RH 02.06
Digital Power Amplifier
Series VRD350 and VRD355
Installation Manual
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
1.2. Ordering Code
Type
Digital
Amplifier for
Proportional
Valves
Module
External
Closed
Loop
Solenoid/
Sensor
Type
Sensor
Assignment
Solenoid
Type
Function
* The values for actual value
signals apply to directio-
nal valves.
Design
Series
Assignment Table
1)
without feedback on valve
2)
with feedback on valve
VRD
Code
Module
350
with front plate
display / and ope-
rating elements
355
without front plate
display / and ope-
rating elements
Code
Type
0
controlled
1
regulated
Code
Solenoid type
1
0.8A
3
2.7A
5
3.5A
7
2.7A
(RLL-central threa-
ded solenoid)
Code
Solenoid / sensor
version
0
Flange solenoids
(or. pos. transdu-
cer with 6V (zero
voltage)
1
Central threaded
solenoids (or
position indicator
with 7.5V null
voltage)
Code Ext. closed loop*
0
without
0
0...±10V
1
4...20mA
2
0...20mA
Code Sensor assignment
0
1)
controlled
1
2)
Flow valves NG6
2
2)
Directional valves NG6
3
2)
Directional valves NG10
4
2)
Directional valves NG16
5
2)
Directional valves NG25
6
2)
Directional valves NG32
7
1)
ext. closed loop
(DC valves)
8
1)
ext. closed loop
(press./flow valves)
9
2)
Directional valve
D91FS
Code
Function
-
controlled
R
regulated
Proportional DC Valves
Amplifier card for valves
Type
Description
Solenoid
Size
without position
transducer
with position
transducer
w/o pos. transducer,
with ext. closed loop
DC Valves
D*1FW
L
10...32
VRD35*-030-00
—
VRD35*-130-R7*
D*1FS
L
10...25
—
VRD35*-130-R*0
—
RLL
G09
6
VRD35*-071-00
VRD35*-171-R20
VRD35*-171-R7*
WLL
G09
6
VRD35*-031-00
VRD35*-131-R20
VRD35*-131-R7*
WLL
—
10
VRD35*-050-00
VRD35*-150-R30
VRD35*-150-R7*
Pressure
Valves
VB
—
6
VRD35*-010-00
—
VRD35*-110-R8*
VBY
—
6...10
VRD35*-010-00
—
VRD35*-110-R8*
VMY
—
6...10
VRD35*-010-00
—
VRD35*-110-R8*
Flow Valves
DUR
—
6
VRD35*-010-00
VRD35*-110-R10
VRD35*-110-R8*